Thermal performance of plastered rice straw bales and walls: a case study

2011· article· en· W1992413344 on OpenAlexvenueno aff
Gihan Garas, Mostafa Allam

Bibliographic record

VenueInternational Journal of Sustainable Development and Planning · 2011
Typearticle
Languageen
FieldEngineering
TopicHygrothermal properties of building materials
Canadian institutionsnot available
Fundersnot available
KeywordsStrawCementLimeRice strawEnvironmental scienceComposite materialMaterials sciencePulp and paper industryWaste managementEngineeringMetallurgyAgronomy

Abstract

fetched live from OpenAlex

Straw, as a fi ber, has been used as part of building materials for several years. A carefully constructed strawbale building has excellent thermal performance because of the combination of the high isolative value of the bales and the thermal mass provided by the thick plaster coating of the interiors. This paper addresses the thermal performance of rice straw bales and walls plastered with different cement plaster mixes. The plaster mixes are applied on straw bales of thickness 45 cm. A fi re resistance test is conducted for two complete hurs on the bales using direct fl ame after which the fl ame was discontinued. According to the test results, the mix with equal parts of cement and lime showed acceptable mechanical properties. This mix is chosen to be applied on a prototype straw bale wall compartment with an aim to evaluate the thermal performance of the plastered straw bale walls in arid desert climate at the hottest month of the year in Egypt. The straw bale wall test is undertaken by collecting actual measurements on site. Thermal sensors are installed on both external and internal sides of the wall to record the heat transmission through the plastered walls. The results showed that all the plastered bales survived fi re penetration for the life period of the test. Increasing the lime content and decreasing the cement content of the mix raises the possibility of weak areas in the plaster of straw bale walls causing cracks during direct fi re exposure. Similar width and density of the bales for all the specimen mixes didn't affect the heat transmission through the bales, which did not exceed 5.3C in all samples. The site readings on the straw bale walls showed high range of temperature fl uctuation on the external wall sensor, while in the internal wall sensor the temperature fl uctuation was kept to minimum values. It was concluded that due to their high thermal insulation, straw bale structures require comparatively less energy to sustain thermal comfort conditions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Qualitative · Consensus signal: Qualitative
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.156
Threshold uncertainty score0.329

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.229
Teacher spread0.202 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designQualitative
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of Sustainable Development and PlanningSame topicHygrothermal properties of building materialsFrench-language works237,207