Accuracy of Linear Measurement Provided by Cone Beam Computed Tomography to Assess Bone Quantity in the Posterior Maxilla: A Human Cadaver Study

2008· article· en· W1992589959 on OpenAlexvenueno aff
Sophie A. Veyre‐Goulet, Thomas Fortin, Anthony Thierry

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2008
Typearticle
Languageen
FieldDentistry
TopicDental Radiography and Imaging
Canadian institutionsnot available
Fundersnot available
KeywordsCalipersCone beam computed tomographyCadaverMaxillaMedicineImage intensifierFiducial markerAnterior maxillaTomographyNuclear medicineComputed tomographyRadiologyOrthodonticsAnatomyMathematicsOptics

Abstract

fetched live from OpenAlex

PURPOSE: The aim of this study was to assess, for implant placement in the posterior maxilla, the accuracy of linear measurements provided by cone beam computed tomography (CBCT) using an image intensifier tube and television (TV) chain as an X-ray detector despite a loss of contrast resolution. The NewTom 9000 (Quantitative Radiology, Verona, Italy) was used to explore the posterior maxilla. MATERIALS AND METHODS: Fourteen measurements were taken in three dry maxillaries. On every anatomical site, three fiducial markers were placed on the bony crest to define a plane. Dry maxillaries were submitted to CBCT imaging examination. The maxillaries were then sawn according to the previously defined planes, and bone height and width were assessed using a caliper. The same measurements were taken on images. RESULTS: Clinical analysis demonstrated no difference between real measurements and image measurements. CONCLUSIONS: Although cadaver bone density may not correspond to the density of vital bone, this in vitro study indicates that CBCT images provided by technique using image intensifier tube and TV chain as an X-ray detector are reliable to define the bone volume of the posterior maxilla for the purpose of planning the implant axis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.022

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.006
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.222
GPT teacher head0.459
Teacher spread0.237 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations108
Published2008
Admission routes1
Has abstractyes

Explore more