MétaCan
Menu
Back to cohort
Record W1992881459 · doi:10.1080/03067319.2014.1002489

Determination of sulfate and chloride ions in highly saline oilfield water by capillary electrophoresis using bilayer-coated capillaries and indirect absorption detection

2015· article· en· W1992881459 on OpenAlexaff
Kingsley K. Donkor, Zhi C. Guo, Laiel C. Soliman, Yuen Ting Law, Jessica M. Risley, Kenneth J. Schmidt, H. John Crabtree, N. A. Warrender

Bibliographic record

VenueInternational Journal of Environmental & Analytical Chemistry · 2015
Typearticle
Languageen
FieldEngineering
TopicMicrofluidic and Capillary Electrophoresis Applications
Canadian institutionsThompson Rivers University
Fundersnot available
KeywordsChemistryChlorideCapillary electrophoresisSulfateChromatographySodium sulfateCertified reference materialsSodiumDetection limit

Abstract

fetched live from OpenAlex

Analysis of highly saline oilfield waters for anions presents challenges. Traditional analytical techniques used for such analysis tend to suffer from both poor sensitivity and selectivity due to the high concentrations of salt present in the samples. A capillary electrophoresis method was developed for the simultaneous determination of chloride and sulfate anions which is relevant to the oilfield analysis industry and of economic value. Due to the extremely high concentrations of chloride in highly saline oilfield waters, it is difficult to achieve baseline electrophoretic separation necessary for accurate quantitation. By using a capillary with a noncovalently bound bilayer coating using Polybrene, a cationic polymer and sodium dodecyl sulfate (SDS), an anionic surfactant and a buffer consisting of 50 mM TRIS, 30 mM SDS, 5% methanol and 26 mM chromium trioxide (CrO3) at pH 6.7, baseline separation (Rs > 1.5) of chloride and sulfate was achieved. To mimic possible oilfield water samples, model water solutions of 5%, 10%, 15% and 20% chloride containing low ppm sulfate were prepared and successfully analysed using the method developed. In addition, the method was applied to determine chloride and sulfate anions in highly saline oilfield water samples. The accuracy of the method developed was verified by analysing NIST certified standards of chloride and sulfate. The results obtained for chloride and sulfate with the indirect CE-UV method were in close agreement (94–100% accuracy; <2.5% relative standard deviations) with those of the certified standard analysed by ion chromatography.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.208
Teacher spread0.201 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of Environmental & Analytical ChemistrySame topicMicrofluidic and Capillary Electrophoresis ApplicationsFrench-language works237,207