MétaCan
Menu
Back to cohort
Record W1992936564 · doi:10.1039/b100671l

Evaluation of a water-jacketed spray chamber using time-of-flight inductively coupled plasma mass spectrometry (TOF-ICP-MS)

2001· article· en· W1992936564 on OpenAlexaff

Bibliographic record

VenueJournal of Analytical Atomic Spectrometry · 2001
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsMemorial University of Newfoundland
Fundersnot available
KeywordsAnalytical Chemistry (journal)ChemistryInductively coupled plasma mass spectrometryMass spectrometryVolumetric flow rateInductively coupled plasmaPlasmaPolyatomic ionOxideDetection limitIonChromatography

Abstract

fetched live from OpenAlex

The application of a water-jacketed spray chamber was evaluated at several temperatures between 4 and 30 °C using a time-of-flight inductively coupled plasma mass spectrometry (TOF-ICP-MS) instrument. As expected when the spray chamber was operated at lower temperatures, less water vapour was transported to the ICP. However, sensitivity (signal per unit concentration) was unchanged when the nebuliser gas flow was optimized at each of the different temperatures, and the expected lowering of the degree of formation of oxide polyatomic ions was not achieved. The effect of lowering the temperature of the water that controlled the temperature of the spray chamber apparently did lower the rate of introduction of water vapour into the ICP. This decrease in water vapour introduced into the ICP resulted in (at the same value of nebuliser gas flow) an apparent increase in plasma temperature. This in turn resulted in a decrease in sensitivity, which was regained by increasing nebuliser gas flow (lower plasma temperature). The maximum sensitivity was comparable at all spray chamber temperatures studied, with higher nebuliser gas flows being required with lower spray chamber temperatures. Other parameters of interest, the background, oxide formation, doubly charged ion formation and detection limits, were comparable at all spray chamber temperatures. This study emphasizes the importance of making multidimensional studies of the ICP-MS. The figure of merit behaviour of the system was comparable to that obtained with first generation quadrupole ICP-MS instruments. With increasing nebuliser gas flow (0.5 to 0.9 l min−1) very striking changes were observed in several parameters. The background decreased from ca. 700 counts s−1 to less than 10 counts s−1; the sensitivity (M counts s−1 ppm−1 abundance−1) varied from very low to a high of ca. 3 and then decreased; the formation of polyatomic oxide ions (using as an example CeO+/Ce+) was approximately 30% at the maximum sensitivity; and the detection limit for Ce reached a minimum of less than 0.01 ppb at an intermediate value of the nebuliser gas flow.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.093
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0270.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.305
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2001
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Analytical Atomic SpectrometrySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207