MétaCan
Menu
Back to cohort
Record W1994141533 · doi:10.1139/l00-025

Laboratory investigation on Fabry-Perot sensor and conventional extensometers for strain measurement in high performance concrete

2000· article· en· W1994141533 on OpenAlexfundvenueno aff
Marco Quirion, Gérard Ballivy

Bibliographic record

VenueCanadian Journal of Civil Engineering · 2000
Typearticle
Languageen
FieldEngineering
TopicAdvanced Fiber Optic Sensors
Canadian institutionsnot available
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsExtensometerMaterials scienceFabry–Pérot interferometerStrain gaugeOptical fiberVibrating wireFiber optic sensorEmbedmentCylinderStructural engineeringLinear variable differential transformerLateral strainComposite materialAcousticsTransformerFiberOpticsOptoelectronicsElectrical engineeringMechanical engineeringEngineeringVoltage

Abstract

fetched live from OpenAlex

Advances in fiber optic sensing technology have made possible the installation of an extremely precise and reliable sensor in small structural members. Because of the high sensitivity and fast response of the sensor, low strain and dynamic strain can be measured. In this study, a Fabry-Perot strain sensor was cast in a high performance concrete cylinder, which had been submitted to simple compression and thermal tests. These results were compared with measurements obtained using external linear variable differential transformers fixed on concrete samples having the same composition as the fiber optic instrumented concrete cylinder. Comparisons were also done with results from tests on concrete cylinders instrumented with embedment vibrating wire and electrical strain gauges. In addition, thermal tests were performed on the different concrete cylinders and samples in order to compare the behaviour of the different sensors in high performance concrete submitted to temperature variations. The results show that the concrete strains measured with the Fabry-Perot sensor are in agreement with strain measurements made on concrete samples. Consequently, the presence of the embedded fiber optic sensor does not influence greatly the mechanical properties of concrete. Furthermore, for high stress levels (0.4 f 'c) and rapid stress changes (0.25 MPa/s), the fiber optic sensor measures with higher accuracy the strains of high performance concrete than the vibrating wire strain gauge.Key words: high performance concrete, sensor, vibrating wire, strain, extensometer, Fabry-Perot, fiber optic, instrumentation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.179
Teacher spread0.164 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2000
Admission routes2
Has abstractyes

Explore more

Same venueCanadian Journal of Civil EngineeringSame topicAdvanced Fiber Optic SensorsFrench-language works237,207