MétaCan
Menu
Back to cohort
Record W1994582829 · doi:10.1117/12.816039

Conducting polymer actuator driven catheter: overview and applications

2009· article· en· W1994582829 on OpenAlexaff
Tina Shoa, Nigel R. Munce, Victor X. D. Yang, John D. W. Madden

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2009
Typearticle
Languageen
FieldEngineering
TopicAdvanced Sensor and Energy Harvesting Materials
Canadian institutionsSunnybrook Health Science CentreUniversity of British Columbia
Fundersnot available
KeywordsActuatorMaterials sciencePolypyrroleOptical coherence tomographyCatheterNanotechnologyComputer scienceConductive polymerPolymerBiomedical engineeringComposite materialPolymerizationOpticsArtificial intelligenceSurgery

Abstract

fetched live from OpenAlex

In this paper conducting polymer based active catheters are presented. Design considerations along with the promise and challenges associated with conducting polymer driven devices are discussed. A conducting polymer driven intravascular catheter is described briefly and its design challenges such as structural rigidity and angle of bending are studied. Then a detailed description of a polypyrrole based active catheter that is ultimately intended for in-vivo imaging applications will be presented. The active catheter contains an optical fibre and is designed to scan the fibre in two dimensions at a speed of 30 Hz to provide real time imaging. The preliminary design was realized by fabricating polypyrrole actuators on a commercially available catheter and patterning the polymer using laser machining technique. The initial device was tested at lower speeds and an image was taken using optical coherence tomography (OCT). The primary challenge to achieving an effective polypyrrole driven catheter for real time imaging is to demonstrate high speed actuation with reasonable liftetime. According to our model, electrochemical characteristics of the conducting polymer such as electronic conductivity, ionic conductivity and electrochemical strain need to be improved to achieve the desired catheter scanning speed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.243
Teacher spread0.222 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicAdvanced Sensor and Energy Harvesting MaterialsFrench-language works237,207