MétaCan
Menu
Back to cohort

Imaging Biomarkers in Atherosclerosis Trials

2011· review· en· W1995338381 on OpenAlexafffund
Jean‐Claude Tardif, Frédéric Lesage, François Harel, Philippe Roméo, Joséphine Pressacco

Bibliographic record

VenueCirculation Cardiovascular Imaging · 2011
Typereview
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsMontreal Heart Institute
FundersCanadian Institutes of Health Research
KeywordsMedicineNuclear medicineCenter (category theory)Internal medicine

Abstract

fetched live from OpenAlex

Advantages and Disadvantages Coronary angiography Coronary lumen 0.4 mm Yes Yes Two-dimensional silhouette of lumen only, associated with cardiovascular events, accepted surrogate for expanded indication IVUS Coronary arterial wall 0.08-0.10mm No Yes, catheter Tomographic, volumetric assessment of changes in plaque burden and vascular remodeling with excellent resolution Carotid ultrasound cIMT and plaque 0.15 mm No No Wide availability, wide clinical trial experience, low cost, technically demanding; further validation of 3D plaque assessment required Coronary CT Coronary lumen and wall 0.4 mm Yes No Rapid acquisition, limited image resolution for plaque burden, radiation exposure MRI Carotid lumen and wall 0.5-1.0mm No No Plaque characterization possible, no validation with clinical events PET Metabolic activity in carotids and aorta 4 mm Yes No Limited image resolution, limited ability to visualize coronary arteries, no validation with clinical events OCT Coronary arterial lumen and wall Excellent, 0.01 mm No Yes, catheter Best image resolution, limited depth of view Requires flushing of lumen NIRS Tissue spectral contrast (chemical assessment) 1 mm No Yes, catheter Link to plaque status not clear, images difficult to interpret, limited spatial registration NIR fluorescence Exogenous, molecular contrast 1 mm No Yes, catheter and injection of molecular compound Limited depth of view due to blood absorption, may require flushing; high potential for molecular imaging; depends on targeted compound approval for humans

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.010
Threshold uncertainty score0.033

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.005
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0020.003
Science and technology studies0.0000.001
Scholarly communication0.0020.002
Open science0.0010.001
Research integrity0.0020.003
Insufficient payload (model declined to judge)0.0100.005

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.108
GPT teacher head0.345
Teacher spread0.237 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations65
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueCirculation Cardiovascular ImagingSame topicCardiac Imaging and DiagnosticsFrench-language works237,207