MétaCan
Menu
Back to cohort
Record W1995794867 · doi:10.1002/maco.200805033

Effect of cathodic protection on macrocell currents: A viable method to monitor and control the efficiency of CP?

2008· article· en· W1995794867 on OpenAlexaff
W. Schwarz, Josef Tritthart

Bibliographic record

VenueMaterials and Corrosion · 2008
Typearticle
Languageen
FieldEngineering
TopicConcrete Corrosion and Durability
Canadian institutionsAS Composite (Canada)
Fundersnot available
KeywordsCathodic protectionCorrosionCoatingMaterials scienceChlorideElectrical conductorComposite materialAnodeMacrocellForensic engineeringElectrodeMetallurgyComputer scienceChemistryEngineeringTelecommunications

Abstract

fetched live from OpenAlex

Abstract Corrosion protection of steel reinforcement in concrete structures by cathodic protection (CP) is a cost effective, reliable, and widely accepted method to stop and prevent the corrosion of the steel reinforcement. The efficiency of CP is usually monitored by the “24 h, 100 mV depolarization criterion,” a purely empirical criterion whose implementation is cost and labor intensive and that does not allow online control of CP. Within an extended research project on CP applied to concrete members of a highway bridge exposed to penetrating moisture, three sets of macrocells (MC), each composed of five MC sensors, were installed in conjunction with concrete resistance sensors and silver/silver chloride reference cells. Chloride profiles were determined from the cored or drilled powder originating from the installation of sensors and from drilling cores. Corrosion currents, steel potentials, and concrete resistance were monitored over a period of 1 year before, after installing the CP systems (which remained switched off for half a year for evaluating the effect of the conductive coating), and after start‐up of the CP systems. The CP systems applied consist of a moisture resistant conductive coating. As expected CP has a pronounced effect on local MC currents: Anodic MC currents were reduced or changed into cathodic currents, whereas cathodic currents were only weakly influenced. By adjusting the applied protection current all anodic MC currents may be changed into cathodic MC currents. Results indicate that the 100 mV depolarization criterion is a conservative criterion in atmospherically exposed concrete; it is not reliable in strongly wetted concrete. There was no consistent correlation between the CP induced changes in the local MC currents and 24 h depolarization values indicating that large potential shifts induced by CP do not necessarily imply overprotection. Results show that monitoring MC currents before, during, and after CP operation allows to demonstrate in a transparent way the effect of CP on the corrosion of the steel reinforcement. Online monitoring of MC currents is proposed as a viable and comprehensible method to monitor and control the efficiency of CP.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.019
Threshold uncertainty score0.283

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.234
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueMaterials and CorrosionSame topicConcrete Corrosion and DurabilityFrench-language works237,207