MétaCan
Menu
Back to cohort
Record W1996008708 · doi:10.1001/archoto.2010.228

Automated Cuff Pressure Modulation

2011· article· en· W1996008708 on OpenAlexaff
Neil K. Chadha, Arie Gordin, Igor Luginbuehl, Greg Patterson, Paolo Campisi, Glenn Taylor, Vito Forte

Bibliographic record

VenueArchives of Otolaryngology - Head and Neck Surgery · 2011
Typearticle
Languageen
FieldMedicine
TopicAirway Management and Intubation Techniques
Canadian institutionsHospital for Sick Children
Fundersnot available
KeywordsCuffIntubationMedicineAirwayAnesthesiaMechanical ventilationVentilation (architecture)ExpirationSurgeryRespiratory systemInternal medicine

Abstract

fetched live from OpenAlex

OBJECTIVE: To assess whether dynamically modulating endotracheal tube (ETT) cuff pressure, by decreasing it during each ventilatory cycle instead of maintaining a constant level, would reduce the extent of intubation-related laryngotracheal injury. DESIGN: Single-blind, randomized controlled animal study using a previously validated live porcine model of accelerated intubation-related tracheal injury. SETTING: Animal research facility. PATIENTS: Ten piglets (weight, 16-20 kg each) were anesthetized and underwent intubation using a cuffed ETT. INTERVENTIONS: The animals were randomized into the following 2 groups: 5 pigs had a novel device to modulate their cuff pressure from 25 cm H₂O during inspiration to 7 cm H₂O during expiration, and 5 pigs had a constant cuff pressure of 25 cm H₂O. Both groups underwent ventilation under hypoxic conditions for 4 hours. MAIN OUTCOME MEASURE: Laryngotracheal mucosal injury after blinded histopathological assessment. RESULTS: The modulated-pressure group showed significantly less overall laryngotracheal damage than the constant-pressure group (mean grades, 1.2 vs 2.1; P < .001). Subglottic damage and tracheal damage were significantly less severe in the modulated-pressure group (mean grades, 1.0 vs 2.2; P < .001, and 1.9 vs 3.2; P < .001, respectively). There was no significant difference in glottic or supraglottic damage between the groups (P = .06 and .27, respectively). CONCLUSIONS: This novel device reduces the risk of subglottic and tracheal injury by modulating ETT cuff pressure in synchronization with the ventilatory cycle. This finding could have far-reaching implications for reducing the risk of airway injury in patients undergoing long-term intubation. Further clinical study of this device is warranted.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.039
Threshold uncertainty score0.388

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.268
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueArchives of Otolaryngology - Head and Neck SurgerySame topicAirway Management and Intubation TechniquesFrench-language works237,207