Impact of distributed generation penetration on grid current harmonics considering non-linear loads

2012· article· en· W1996323999 on OpenAlexaff
Vinod Khadkikar, Rajiv K. Varma, Ravi Seethapathy, Ambrish Chandra, Hatem Zeineldin

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicMicrogrid Control and Optimization
Canadian institutionsÉcole de Technologie SupérieureHydro One (Canada)Western University
Fundersnot available
KeywordsHarmonicsTotal harmonic distortionPhotovoltaic systemDistributed generationElectrical engineeringInverterSynchronizingElectronic engineeringGridComputer scienceControl theory (sociology)EngineeringAutomotive engineeringVoltageRenewable energyTopology (electrical circuits)Mathematics

Abstract

fetched live from OpenAlex

In this paper, the impact of large-scale penetration of distributed generation (DG) system in the presence of non-linear loads is addressed. The effect of different DG penetration levels on the grid side current harmonics is examined. It is found that current harmonics generated by downstream non-linear loads with a TDD (total demand distortion) that is compliant with IEEE Standards can lead to significantly high THD (total harmonic distortion) values at the grid side under certain loading scenarios. These low magnitude highly distorted currents may cause protection circuitry and grid-synchronizing circuitry malfunctioning, and may even cause a resonance condition with power factor correction capacitor on the network. This paper further presents a control application of Photovoltaic (PV) solar plant based DG inverter o mitigate the above harmonics problem. The increased harmonic level issue and the application of PV solar plant to mitigate such problem have been demonstrated both by MATLAB/ SIMULINK simulation studies and laboratory experimental results.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.266
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations37
Published2012
Admission routes1
Has abstractyes

Explore more

Same topicMicrogrid Control and OptimizationFrench-language works237,207