MétaCan
Menu
Back to cohort
Record W1996653725 · doi:10.1097/bcr.0b013e3181710881

Quantitative Measurement of Hypertrophic Scar: Interrater Reliability and Concurrent Validity

2008· article· en· W1996653725 on OpenAlexaffabout
Bernadette Nedelec, José A. Correa, Grazyna Rachelska, Alexis Armour, Léo LaSalle

Bibliographic record

VenueJournal of Burn Care & Research · 2008
Typearticle
Languageen
FieldMedicine
TopicDermatologic Treatments and Research
Canadian institutionsUniversité de MontréalMcGill University
Fundersnot available
KeywordsMedicineIntraclass correlationInter-rater reliabilityVascularityHypertrophic scarNuclear medicineSurgeryStatisticsMathematicsPsychometricsRating scale

Abstract

fetched live from OpenAlex

Research into the pathophysiology and treatment of hypertrophic scar (HSc) remains limited by the heterogeneity of scar and the imprecision with which its severity is measured. The objective of this study was to test the interrater reliability and concurrent validity of the Cutometer measurement of elasticity, the Mexameter measurement of erythema and pigmentation, and total thickness measure of the DermaScan C relative to the modified Vancouver Scar Scale (mVSS) in patient-matched normal skin, normal scar, and HSc. Three independent investigators evaluated 128 sites (severe HSc, moderate or mild HSc, donor site, and normal skin) on 32 burn survivors using all of the above measurement tools. The intraclass correlation coefficient, which was used to measure interrater reliability, reflects the inherent amount of error in the measure and is considered acceptable when it is >0.75. Interrater reliability of the totals of the height, pliability, and vascularity subscales of the mVSS fell below the acceptable limit ( congruent with0.50). The individual subscales of the mVSS fell well below the acceptable level (< or =0.3). The Cutometer reading of elasticity provided acceptable reliability (>0.89) for each study site with the exception of severe scar. Mexameter and DermaScan C reliability measurements were acceptable for all sites (>0.82). Concurrent validity correlations with the mVSS were significant except for the comparison of the mVSS pliability subscale and the Cutometer maximum deformation measure comparison in severe scar. In conclusion, the Mexameter and DermaScan C measurements of scar color and thickness of all sites, as well as the Cutometer measurement of elasticity in all but the most severe scars shows high interrater reliability. Their significant concurrent validity with the mVSS confirms that these tools are measuring the same traits as the mVSS, and in a more objective way.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.038
metaresearch head score (Gemma)0.092
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: Methods · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.962
Threshold uncertainty score0.201

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0380.092
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.002
Scholarly communication0.0010.001
Open science0.0010.002
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.331
GPT teacher head0.449
Teacher spread0.118 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

Study designObservational
DomainMethods
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations126
Published2008
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Burn Care & ResearchSame topicDermatologic Treatments and ResearchFrench-language works237,207