MétaCan
Menu
Back to cohort
Record W1997943094 · doi:10.1080/03067310903254610

Determination of zinc in marine/lacustrine sediments by graphite furnace atomic absorption spectrometry using Pd/Mg chemical modifier and slurry sampling

2011· article· en· W1997943094 on OpenAlexaboutno aff
Junling Bai, Toshifumi Nakatani, Yuuki Sasaki, Hirotsugu Minami, Sadanobu Inoue, Nobuo Takahashi

Bibliographic record

VenueInternational Journal of Environmental & Analytical Chemistry · 2011
Typearticle
Languageen
FieldChemistry
TopicAnalytical chemistry methods development
Canadian institutionsnot available
FundersJapan Society for the Promotion of Science
KeywordsCertified reference materialsSlurryGraphite furnace atomic absorptionSedimentZincAtomic absorption spectroscopyNitric acidChemistryAnalytical Chemistry (journal)Environmental chemistryCalibration curveMass spectrometryDetection limitEnvironmental scienceChromatographyInorganic chemistryGeologyEnvironmental engineering

Abstract

fetched live from OpenAlex

Abstract Effectiveness of Pd/Mg chemical modifier for the accurate direct determination of zinc in marine/lacustrine sediments by graphite furnace atomic absorption spectrometry (GF-AAS) using slurry samples was evaluated. A calibration curve prepared by aqueous zinc standard solution with addition of Pd/Mg chemical modifier is used to determine the zinc concentration in the sediment. The accuracy of the proposed method was confirmed using Certified Reference Materials, NMIJ CRM 7303-a (lacustrine sediment) from National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Japan, and MESS-3 (marine sediment) and PACS-2 (marine sediment) from National Research Council, Canada. The analytical results obtained by employing Pd/Mg modifier are in good agreement with the certified values of all the reference sediment materials. Although for NRC MESS-3 an accurate determination of zinc is achieved even without the chemical modifier, the use of Pd/Mg chemical modifier is recommended as it leads to establishment of a reliable and accurate direct analytical method. One quantitative analysis takes less than 15 minutes after we obtain dried sediment samples, which is several tens of times faster than conventional analytical methods using acid digested sample solutions. The detection limits are 0.13 µg g−1 (213.9 nm) and 16 µg g−1 (307.6 nm), respectively, in sediment samples, when 40 mg of dried powdered samples are suspended in 20 mL of 0.1 mol L−1 nitric acid and a 10 µl portion of the slurry sample is measured. The precision of the proposed method is 8–15% (RSD). Keywords: graphite furnace atomic absorption spectrometry (GF-AAS)slurry samplingmarine and lacustrine sedimentszincchemical modifierpalladiummagnesium Acknowledgement This work was supported by the funding agency in Japan: The Japan Society for the Promotion of Science KAKENHI (No. 19550077).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.030
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.284
Teacher spread0.256 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of Environmental & Analytical ChemistrySame topicAnalytical chemistry methods developmentFrench-language works237,207