Capacitive Micromachined Ultrasonic Transducer Array with Pencil Beam Shape and Wide Range Beam Steering
Bibliographic record
Abstract
Abstract A capacitive micromachined ultrasonic transducer (CMUT) array is designed as an alternative to conventional piezoelectric transducers. A thin silicon nitride membrane is suspended over a bottom electrode on a silicon wafer. In the immersion mode, the transducer cell shape and dimensions are optimized for an operating frequency of 10 MHz. We show that the proposed imager array can generate a pencil shape beam with a ∼1.5° half beam width, enhancing the detector resolution. A phased array technique is employed to excite multiple cells using time-delayed signals to steer the acoustic beam toward the object. This eliminates the need to mechanically move the detector, simplifying the transducer driving system. Moreover, unlike conventional transducers, the pencil beam can be effectively steered over a wide range of angles without producing grating lobes, which minimizes power loss in undesired directions. This can also improve the signal to noise ratio of the imager CMUT array.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.001 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".