First demonstration of intrafractional tumor‐tracked irradiation using 2D phantom MR images on a prototype linac‐MR
Bibliographic record
Abstract
PURPOSE: To demonstrate intrafractional MR tumor tracking using a prototype linac-MR by delivering radiation to a moving target undergoing simulated tumor motions. METHODS: A prototype linac-MR at the Cross Cancer Institute was used for intrafractional MR imaging and simultaneous beam delivery. A Varian 52-leaf MK-II multileaf collimator (MLC) was used for beam collimation. The authors used an inhouse built MR compatible motion phantom to simulate tumor motions during tracking with two different motion patterns (sine and modified cosine). Gafchromic film was inserted in the phantom to measure radiation exposure, and this film measurement was converted to dose (cGy) for further analysis. The authors demonstrated intrafractional tracking in various scenarios: [Scenario 0 (S0)] no phantom motion + no beam margin, (S1) no phantom motion + maximum beam margin, (S2) phantom motion + no beam margin, (S3) S2 + MLC tracking, and (S4) S3 + motion prediction. S0 emulates a perfect tumor tracking scenario, and its result was used as a "gold-standard" to evaluate tracking accuracy from other scenarios. The authors compared (1) time difference in phantom and MLC motion curves in S3 and S4, and (2) dose profiles (50% beam width, 80%-20% penumbra width) from scenarios S1-S4 to S0. RESULTS: In S4, no observable time difference exists between the phantom and MLC motion curves, indicating that MLC tracks phantom motion accurately. Comparing S4 to S0, 50% beam width reveals minimal differences of < 0.5 mm, while the increase in 80%-20% penumbra width is limited to 0.4 and 1.7 mm in the sine and modified cosine patterns, respectively. CONCLUSIONS: The authors report the first demonstration of intrafractional tumor tracking using 2D MR images. During 2 min of tracking, the authors delivered highly conformal dose to a moving target that simulates tumor motions. Compared to static target irradiation, the 50% beam width remains essentially the same (within 0.5 mm), with an increase in 80%-20% penumbra width of less than 1.7 mm in moving target irradiation. These results illustrate potential dosimetric advantages of intrafractional MR tumor tracking in treating mobile tumors as shown for the phantom case.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".