MétaCan
Menu
Back to cohort
Record W1998583416 · doi:10.1520/jai103344

An Overview of Progress and New Developments in FTIR Lubricant Condition Monitoring Methodology

2011· article· en· W1998583416 on OpenAlexaff
F.R. van de Voort, Jacqueline Sedman, D. V. Pinchuk

Bibliographic record

VenueJournal of ASTM International · 2011
Typearticle
Languageen
FieldChemistry
TopicSpectroscopy and Chemometric Analyses
Canadian institutionsThermal-Lube (Canada)McGill University
Fundersnot available
KeywordsFourier transform infrared spectroscopyLubricantProcess engineeringBase oilMaterials scienceEnvironmental scienceMoistureComputer sciencePulp and paper industryBiochemical engineeringChemical engineeringEngineeringComposite material

Abstract

fetched live from OpenAlex

Abstract Fourier transform infrared (FTIR) spectroscopy has found an important analytical niche in the field of condition monitoring (CM) of lubricants, lubricant quality being a primary determinant of the wear and operational efficiency of engines and machinery. The ability to track a wide range of functional groups associated with chemical changes in lubricants by FTIR spectroscopy allows the overall quality of lubricants to be assessed and informed decisions made as to whether a lubricant needs to be replaced or not. Newer automated FTIR systems in centralized laboratories are now capable of analyzing oil samples at rates of>120 samples/h, providing trending information on soot, moisture, glycol, oxidative status, anti-wear additives, and nitration, amongst other measures. The current FTIR CM methodology is based on ASTM Standard Practice E2412-10 and is restricted primarily to petroleum or mineral oils; however, the ability to spectrally classify oils could overcome this limitation and broaden the scope of the methodology substantially. Quantitative FTIR methods have come to the fore to carry out more specific measures related to oil condition, specifically the determination of acid content and base content, as well as moisture. These methods have been designed to overcome some key limitations associated with the corresponding ASTM titrimetric procedures and expand the overall utility of FTIR instrumentation in centralized lubricant analysis laboratories. This paper provides an overview of FTIR CM, how it has been and can be further improved, and discusses the recent advances in the newer quantitative FTIR CM methods as well as the issues that need to be addressed to further enhance the utility of FTIR spectroscopy in relation to lubricant analysis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.457
Threshold uncertainty score0.833

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.290
GPT teacher head0.446
Teacher spread0.156 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations25
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueJournal of ASTM InternationalSame topicSpectroscopy and Chemometric AnalysesFrench-language works237,207