MétaCan
Menu
← Back to cohort
Record W1998954234 · doi:10.1118/1.2760581

SU-FF-J-76: Inter-Fractional Prostate Motion Measured with 3D Daily Ultrasound Images

2007· article· en· W1998954234 on OpenAlexaboutno aff
T Neicu, S Li, Benjamin Movsas

Bibliographic record

VenueMedical Physics · 2007
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsnot available
Fundersnot available
KeywordsUltrasoundProstateMedicineImage-guided radiation therapyNuclear medicineProstate cancer3D ultrasoundUltrasonographyVolume (thermodynamics)Displacement (psychology)Medical imagingRadiologyCancerPhysics

Abstract

fetched live from OpenAlex

Purpose: to assess inter-fractional prostate displacement using a 3D ultrasound-based localization system Materials and methods: IGRT program in our department has been recently enhanced through implementation of a 3D ultrasound-guided system from Resonant Medical Inc. (Montreal, Canada) that combines ultrasonography, optical tracking, and computer technology. During the CT simulation, two ultrasound scans were taken and the best defined target was saved as the Positioning Reference Volume (PRV). At each treatment session, the patient was initially setup using the room lasers aligned with skin marks and then an ultrasound scan was taken and a new target volume would be automatically or manually created. The system computed the required shifts to align the new target volume to the PRV and the treatment couch was moved accordingly. As of now, 52 prostate cancer patients were positioned for treatment using the system. Eleven of them were initially positioned using bony structures shown in portal images and then moved with the ultrasound guidance. The inter-fractional prostate motion related to skin or bony marks were both analyzed. Results: The average target displacements in the left-right, superior-inferior, and anterior-posterior directions relative to skin marks were 3.9 +/− 2.8, 4.5 +/− 3.0 and 4.9 +/− 3.4 mm, respectively. The standard deviation of the prostate motion slightly decreases with the increase of the PRV volume. Repeated ultrasound scans at the simulation show significant variation (SD > 5 mm) for earlier patients with a great improvement (SD < 4 mm) for the later patients. We found that there is no additional target precision obtained by bony structure-based positioning relative to the skin marks localization. Conclusion: The target motion is significant and may represent the daily variation of the rectal and bladder fillings. The relatively large standard deviation of prostate motion could be slightly improved with the increase of user's experience.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.271
Teacher spread0.264 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→