MétaCan
Menu
Back to cohort
Record W1999027093 · doi:10.1021/es901261v

Branched Perfluorooctane Sulfonate Isomer Quantification and Characterization in Blood Serum Samples by HPLC/ESI-MS(/MS)

2009· article· en· W1999027093 on OpenAlexaff
Nicole Riddell, Gilles Arsenault, Jonathan P. Benskin, Brock Chittim, Jonathan W. Martin, Alan J. McAlees, Robert McCrindle

Bibliographic record

VenueEnvironmental Science & Technology · 2009
Typearticle
Languageen
FieldEnvironmental Science
TopicPer- and polyfluoroalkyl substances research
Canadian institutionsUniversity of GuelphUniversity of Alberta
Fundersnot available
KeywordsPerfluorooctaneChemistryChromatographyEnvironmental chemistrySulfonateHuman bloodOrganic chemistryPhysiology

Abstract

fetched live from OpenAlex

Perfluorooctane sulfonate (PFOS) is a global contaminant and is currently among the most prominent contaminants in human blood and wildlife samples. Although "total PFOS" (SigmaPFOS) analytical methods continue to be the most commonly used for quantification, recent analytical method developments have made it possible to resolve the various isomers of PFOS by HPLC-MS/MS. Characterized technical PFOS standards (i.e., containing a mixture of PFOS isomers) are now available that enable isomer specific quantification of PFOS, however the advantages of such an analysis have notyet been examined systematically. Herein, PFOS isomers have been individually quantified for the first time in real samples and the results are compared to a traditional SigmaPFOS method; the influence of analytical standards and isomer specific electrospray and MS/ MS behavior were also investigated. The two human serum standard reference materials chosen for analysis contained dramaticallydifferent PFOS isomer profiles (approximately 30-50% total branched isomers) emphasizing that isomer patterns should not be ignored and may provide useful information on exposure sources (i.e., direct exposure to PFOS vs indirect exposure from PFOS-precursors). Depending on the sample and the particular MS/MS transition chosen for SigmaPFOS analysis (i.e., 499-->80 or 499-->99), SigmaPFOS concentrations may be over- or underestimated compared to the isomer specific analysis. Differences in the extent of in-source fragmentation and MS/MS dissociation contributed to the systematic analytical bias. It was also shown that SigmaPFOS data are prone to interlaboratory variation due to various choices of PFOS standards and instrumental conditions used. In the future, for either SigmaPFOS or isomer specific PFOS analyses, we suggest that accuracy can be maximized and interlaboratory discrepancies minimized by using a common chemically pure technical PFOS standard characterized by 19F NMR.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.523
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.002
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.233
Teacher spread0.224 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations119
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueEnvironmental Science & TechnologySame topicPer- and polyfluoroalkyl substances researchFrench-language works237,207