MétaCan
Menu
Back to cohort
Record W2001297297 · doi:10.1002/pbc.22649

A radiotherapy planning study of RapidArc, intensity modulated radiotherapy, three‐dimensional conformal radiotherapy, and parallel opposed beams in the treatment of pediatric retroperitoneal tumors

2010· article· en· W2001297297 on OpenAlexaff
Richard Shaffer, E. Vollans, R. Vellani, Margaret Welsh, Vitali Moiseenko, Karen Goddard

Bibliographic record

VenuePediatric Blood & Cancer · 2010
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsBC Cancer Agency
Fundersnot available
KeywordsMedicineRadiation therapyRadiologyRadiation treatment planningMedical physics

Abstract

fetched live from OpenAlex

BACKGROUND: This planning study compared RapidArc, fixed-field IMRT (cIMRT), 3D conformal radiotherapy (3D-CRT), and a parallel-opposed pair (POP) for children with retroperitoneal tumors. PROCEDURE: Plans were generated in eight patients to treat the PTV (dose range 19.8-45 Gy) while limiting kidney and liver doses. In selected patients, vertebral body (VB) dose heterogeneity was minimized. Cumulative DVH parameters, monitor units (MU), and treatment times were compared for the four techniques using the Wilcoxon matched pairs test. RESULTS: RapidArc and cIMRT covered target volumes more conformally than 3D-CRT and POP (P = 0.012). There was no difference in the ability to meet kidney dose constraints. A significantly lower volume of the liver received 12 Gy with cIMRT or RapidArc compared with 3D-CRT (P = 0.028). Where VB was included in PTV, VB dose homogeneity was generally within 94-104% of the prescription dose. Time to deliver a single fraction with RapidArc, POP, 3D-CRT, and cIMRT was 1.25 ± 0.01, 1.38 ± 0.10, 2.6 ± 0.45, and 4.02 ± 1.12 min, respectively (P = 0.012). Monitor units for a single fraction with POP, 3D-CRT, RapidArc, and cIMRT were 203 ± 26, 235 ± 32, 325 ± 71, and 665 ± 215, respectively (P < 0.05). CONCLUSIONS: POP resulted in favorable MU, treatment time and dosimetry but had poor conformality. 3D-CRT was more conformal but had higher MU and treatment time. RapidArc and cIMRT were generally no better dosimetrically than conformal techniques. RapidArc was dosimetrically very similar to cIMRT, but resulted in a major reduction in time and MU used to deliver the radiation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.065
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.283
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2010
Admission routes1
Has abstractyes

Explore more

Same venuePediatric Blood & CancerSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207