MétaCan
Menu
← Back to cohort
Record W2002529235 · doi:10.1118/1.1997417

SU‐CC‐J‐6C‐11: Verification of IMRT Dose Distributions Using a Tissue Equivalent Plastic Scintillator Based Dosimetry System

2005· article· en· W2002529235 on OpenAlexaff
MP Petric, JL Robar, BG Clark

Bibliographic record

VenueMedical Physics · 2005
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsNova Scotia Cancer CentreBC Cancer Agency
Fundersnot available
KeywordsDosimetryScintillatorImaging phantomCalibrationOpticsCollimatorQuality assuranceMaterials scienceDose profileNuclear medicineMedical physicsPhysicsComputer scienceDetectorMedicine

Abstract

fetched live from OpenAlex

Purpose: Intensity modulated radiation therapy (IMRT) offers the potential for improved target coverage and increased normal tissue sparing compared with conformal radiotherapy. The complex fluence maps used in IMRT, however, lead to more challenging quality assurance with dose verification being labor‐intensive and time consuming. An IMRT dose verification system has been developed using tissue equivalent plastic scintillator that provides easy to acquire, rapid electronic and directly digital dose measurements of a 2D plane perpendicular to the beam. Method and Materials: The prototype system consists of a water‐filled Lucite phantom with a scintillator screen built into the top surface. The phantom contains a plastic mirror to reflect scintillation light towards a viewing window where it is captured using a CCD camera and a personal computer. Optical photon spread is removed using a micro‐louvre optical collimator and by deconvolving a glare kernel from the raw images. System calibration is performed using radiation fields of known dose distributions. The system was evaluated by verifying a 5‐field IMRT plan and comparing the results to a 2‐D film dosimetry verification of the same plan. Resultant distributions were compared using 1‐D dose profiles, 2‐D dose difference maps and gamma factor analysis. A comparison of the time requirements for verification with each system was also performed. Results: Preliminary results acquired with the new verification system indicate agreement within 5% of 2‐D film dosimetry. Gamma factor analysis shows excellent agreement over most of the distributions. The timing comparison of the verification systems highlights the efficiency of the new scintillator system for IMRT verification with a 50% reduction in time. Conclusion: Results from a 5‐field IMRT plan verification using the new scintillator based system are very promising. With further development this system promises to provide a fast, directly digital, and tissue equivalent alternative to current IMRT verification systems.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.307
Teacher spread0.292 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→