MétaCan
Menu
Back to cohort

Biomechanical Comparison of Six Suture Configurations Using a Large Diameter Polyester Prosthesis in the Muscular Process of the Equine Arytenoid Cartilage

2008· article· en· W2002711710 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueVeterinary Surgery · 2008
Typearticle
Languageen
FieldMedicine
TopicVoice and Speech Disorders
Canadian institutionsUniversity of Saskatchewan
FundersJohnson and Johnson
KeywordsCadaveric spasmMedicineFibrous jointArytenoid cartilageBiomechanicsProsthesisAnatomyOrthodonticsSurgeryBiomedical engineeringLarynx

Abstract

fetched live from OpenAlex

OBJECTIVE: To compare biomechanical properties of 6 suture configurations using a large diameter polyester prosthesis in the muscular process (MP) of the arytenoid cartilage and to determine failure mode. STUDY DESIGN: Experimental study. SAMPLE POPULATION: Cadaveric equine larynges (n=121). METHODS: Suture configurations (4 single, 2 double) were inserted, and then constructs were tested in a single-cycle to failure at a 100 mm/min distraction. Load deformation curves were generated to assess the biomechanical properties of each construct. A 1-way ANOVA was used to compare the mean differences in construct failure force, cricoarytenoid joint (CAJ) disarticulation force, and energy stored at failure. A 2-sample t-test was used to compare single versus double suture patterns and a Fisher's exact test was used to compare failure mode. RESULTS: Both construct and CAJ failure force were significantly greater (P<.05) for double suture patterns compared with single suture patterns; however, there were no significant differences in energy stored at construct failure. Failure at the MP accounted for >or=50% of construct failures for 3 of the single suture patterns and 1 of the double suture patterns tested. The remaining 2 patterns had an increased frequency of clamp failures as well as failure of the cricoid cartilage. CONCLUSIONS: Sutures that sufficiently engage the spine of the MP alone or in conjunction with a second suture were found to be biomechanically superior. CLINICAL RELEVANCE: Engaging the spine of the MP appears to result in the most biomechanically sound laryngeal construct.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.353
Threshold uncertainty score0.355

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.090
GPT teacher head0.342
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it