MétaCan
Menu
Back to cohort
Record W2003627088 · doi:10.1128/jcm.03203-12

Evaluation of an Algorithmic Approach in Comparison with the Illumigene Assay for Laboratory Diagnosis of Clostridium difficile Infection

2013· article· en· W2003627088 on OpenAlexaffabout
Andrew Walkty, Philippe Lagacé‐Wiens, K. Manickam, Heather J. Adam, Peter Pieroni, D. Hoban, James A. Karlowsky, Michelle J. Alfa

Bibliographic record

VenueJournal of Clinical Microbiology · 2013
Typearticle
Languageen
FieldMedicine
TopicClostridium difficile and Clostridium perfringens research
Canadian institutionsUniversity of ManitobaShared HealthHealth Sciences Centre
Fundersnot available
KeywordsClostridium difficileAlgorithmGlutamate dehydrogenaseTurnaround timePositive predicative valueMedicinePredictive valueClostridium difficile toxin AAntigenMicrobiologyBiologyInternal medicineImmunologyAntibioticsComputer science

Abstract

fetched live from OpenAlex

The following three diagnostic algorithms were evaluated in comparison with the Illumigene assay as a stand-alone test for Clostridium difficile detection: glutamate dehydrogenase antigen screen (GDH) followed by toxin A/B antigen testing (Tox A/B) with the cell cytotoxicity assay for discordant specimens (algorithm 1), GDH followed by the Illumigene (algorithm 2), and GDH followed by Tox A/B with the Illumigene for discordant specimens (algorithm 3). A total of 428 stool specimens submitted to three clinical microbiology laboratories in Manitoba, Canada, for C. difficile detection between June 2011 and April 2012 were included in the study. The prevalence of C. difficile in the stool specimens was 14.7% (63/428) based on toxigenic culture (microbiologic reference standard). The sensitivity and specificity of the Illumigene for C. difficile detection were 73.0% and 99.7%, respectively. The corresponding sensitivities and specificities were 65.1% and 100.0% for algorithm 1, 68.3% and 100.0% for algorithm 2, and 69.8% and 100.0% for algorithm 3. Using algorithm 1, a cell cytotoxicity assay was required for toxin detection in 37% of positive tests, prolonging turnaround time. However, the predictive value of a positive test based on a clinical reference standard (all tests positive or cytotoxigenic culture positive and clinical disease on chart review) was slightly higher with algorithm 1 than with the Illumigene assay as a stand-alone test or as part of an algorithm (algorithms 2 and 3). Based on a reduction in turnaround time, simplicity, and acceptable sensitivity and specificity, we recommend algorithm 2 (screening with the GDH antigen test and confirmatory testing with the Illumigene).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.029
metaresearch head score (Gemma)0.060
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.029
Threshold uncertainty score0.153

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0290.060
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.002
Science and technology studies0.0000.001
Scholarly communication0.0030.002
Open science0.0020.002
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.087
GPT teacher head0.407
Teacher spread0.320 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2013
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Clinical MicrobiologySame topicClostridium difficile and Clostridium perfringens researchFrench-language works237,207