Baroreflex Sensitivity of an Arterial Wall During Rotary Blood Pump Assistance
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
It is well known that the baroreflex system is one of the most important indicators of the pathophysiology in hypertensive patients. We can check the sensitivity of the baroreflex by observing heart rate (HR) responses; however, there is no simple diagnostic method to measure the arterial behavior in the baroreflex system. Presently, we report the development of a method and associated hardware that enables the diagnosis of baroreflex sensitivity by measuring the responses of both the heart and the artery. In this system, the measurements are obtained by monitoring an electrocardiogram and a pulse wave recorded from the radial artery or fingertip. The arterial responses were measured in terms of the pulse wave velocity (PWV) calculated from the pulse wave transmission time (PTT) from the heart to the artery. In this system, the HR change corresponding to the blood pressure change in time series sequence was observed. Slope of the changes in blood pressure and HR indicated the sensitivity of the baroreflex system of the heart. This system could also measure the sensitivity of the baroreflex system of an artery. Changes in the PWV in response to the blood pressure changes were observed. Significant correlation was observed in the time sequence between blood pressure change and PWV change after calculating the delay time by cross-correlation. The slope of these parameter changes was easily obtained and it demonstrated the sensitivity of the baroreflex system of an artery. We evaluated this method in animal experiments using rotary blood pump (RBP) with undulation pump ventricular assist device, and PTT elongation was observed in response to increased blood pressure with RBP assistance. Furthermore, when tested clinically, decreased sensitivity of the baroreflex system in hypertensive patients was observed. This system may be useful when we consider the ideal treatment and follow-up of patients with hypertension.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it