MétaCan
Menu
Back to cohort
Record W2006250603 · doi:10.1097/eja.0b013e32832b138d

Heart rate/blood pressure response and airway morbidity following tracheal intubation with direct laryngoscopy, GlideScope and Trachlight: a randomized control trial

2009· article· en· W2006250603 on OpenAlexaffabout
Naveed Siddiqui, Rita Katznelson, Zeev Friedman

Bibliographic record

VenueEuropean Journal of Anaesthesiology · 2009
Typearticle
Languageen
FieldMedicine
TopicAirway Management and Intubation Techniques
Canadian institutionsToronto General HospitalUniversity of TorontoMount Sinai Hospital
Fundersnot available
KeywordsMedicineLaryngoscopyIntubationAnesthesiaTracheal intubationHemodynamicsHaemodynamic responseSore throatHeart rateBlood pressureAirway managementAirwayElective surgerySurgeryInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND AND OBJECTIVE: Haemodynamic response to tracheal intubation might be detrimental in high-risk patients. Minimizing oropharyngo-laryngeal stimulation or avoiding laryngoscopy may attenuate this response. We hypothesized that intubations performed with GlideScope or Trachlight would generate a lesser haemodynamic response than the conventional method of direct laryngoscopy. The objective of this study was to compare the haemodynamic response following tracheal intubation, using three different techniques of intubation. We also examined postoperative airway morbidities as our secondary outcome. METHODS: This was a prospective randomized control trial, conducted at Mount Sinai Hospital of Toronto. After Ethics Board approval, 60 adult ASA status I and II patients, scheduled for elective surgery requiring general anaesthesia with orotracheal intubation, were randomly allocated into three groups. Intubation was performed by a single experienced anaesthesiologist, using direct laryngoscopy, GlideScope or Trachlight. The haemodynamic variables were measured noninvasively at specific time intervals. We also recorded the number of attempts and total time for intubation. Postoperative airway symptoms following surgery were assessed using a questionnaire. RESULTS: There was no significant difference in blood pressure and heart rate between the groups. Direct laryngoscopy intubation times were significantly lower than those of the other techniques (both P<0.0001). The occurrence of sore-throat symptoms in recovery was significantly higher in the Trachlight group (P=0.0033). CONCLUSION: There was no benefit of using any of the three intubation techniques for attenuation of haemodynamic changes. There was a higher incidence of airway symptoms associated with Trachlight intubation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.287
Threshold uncertainty score0.521

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0060.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.251
Teacher spread0.241 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations52
Published2009
Admission routes2
Has abstractyes

Explore more

Same venueEuropean Journal of AnaesthesiologySame topicAirway Management and Intubation TechniquesFrench-language works237,207