Case Study on Cost Saving and GHG Emission Reduction From Coupling Air Source Heat Pump With Photovoltaic/Thermal Collector

2014· article· en· W2007373383 on OpenAlexafffundabout
Raghad Sabah Kamel, Alan S. Fung

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsToronto Metropolitan University
FundersNatural Sciences and Engineering Research Council of CanadaMitacs
KeywordsTRNSYSPhotovoltaic systemHeat pumpElectricityBuilding-integrated photovoltaicsEnvironmental scienceCost of electricity by sourceAir source heat pumpsAutomotive engineeringNuclear engineeringElectricity generationWaste managementThermalMeteorologyEngineeringElectrical engineeringMechanical engineeringHeat exchangerPower (physics)

Abstract

fetched live from OpenAlex

TRNSYS simulation software was used to modify a validated Air Source Heat Pump (ASHP) model in an Archetype Sustainable House (ASH) in Toronto. In this model, a Building Integrated Photovoltaic-Thermal Collector (BIPV/T) was coupled with ASHP. The PV/T system arrangement was considered as a part of the south-oriented roof of the house. The warm air generated in the BIPV/T collector was considered the source of the heat pump for heat production. The coupling of BIPV/T and ASHP enables a highly efficient heating system in harsh winter conditions. The developed TRNSYS model of the house along with integrated PV/T system with ASHP was simulated for the whole year to predict the hourly outlet air temperature, thermal energy and electricity obtained from the PV/T array. The results from the simulation were used to estimate the saving in energy and cost as well as to predict the electricity related GHG emission reduction potential from the PV panels. Monthly greenhouse gas (GHG) emission credit from PV production based on hourly GHG emission factor was obtained; the results showed that annual GHG emission due to electricity demand by the ASHP was reduced by 225 kg CO2 (19.3%) when the heat pump was integrated with the PV/T array. Also, in this study, the annual electricity cost credit from PV production based on Time-of-Use (TOU) and the reduction in electricity cost of the heat pump when connected with PV/T systems was calculated and compared with the cost of working the heat pump alone. The results show that there is a saving of $500 in annual electricity bills and GHG emission credit of 862.6 kg CO2 from renewable electricity generation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.041
Threshold uncertainty score0.081

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.198
Teacher spread0.189 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2014
Admission routes3
Has abstractyes

Explore more

Same topicBuilding Energy and Comfort Optimization→French-language works237,207→