MétaCan
Menu
Back to cohort
Record W2007658443 · doi:10.1243/09576509jpe532

Developing and testing a generic micro-combined heat and power model for simulations of dwellings and highly distributed power systems

2008· article· en· W2007658443 on OpenAlexaff
Nick Kelly, J.A. Clarke, Alex Ferguson, Graeme Burt

Bibliographic record

VenueProceedings of the Institution of Mechanical Engineers Part A Journal of Power and Energy · 2008
Typearticle
Languageen
FieldEngineering
TopicThermodynamic and Exergetic Analyses of Power and Cooling Systems
Canadian institutionsNatural Resources Canada
FundersEngineering and Physical Sciences Research Council
KeywordsWork (physics)Power (physics)Automotive engineeringStirling engineHeating systemReliability engineeringCalibrationComputer scienceSimulationEnvironmental scienceEngineeringMechanical engineering

Abstract

fetched live from OpenAlex

This paper elaborates an approach to the modelling of domestic micro-combined heat and power (μ-CHP) using a building simulation tool that can provide a detailed picture of the environmental performance of both the μ-CHP heating system and the dwelling it serves. The approach can also provide useful data for the modelling of highly distributed power systems (HDPS). At the commencement of the work described in this paper no μ-CHP device model that was compatible with a building simulation tool was available. The development of such a model is described along with its calibration and verification. The simulation tool with the device model was then applied to the analysis of a dwelling with a Stirling engine-based heating system. Different levels of thermal insulation and occupancy types were modelled. The energy and environmental performance of the μ-CHP device was quantified for each case; additionally, the potential for its participation in the control and operation of an HDPS was assessed. Analysis of the simulation results indicated that the parasitic losses associated with the μ-CHP system balance of plant reduced the overall heating system efficiency by up to 40 per cent. Performance deteriorated with increasing levels of insulation in the dwelling, resulting in reduced thermal efficiency and increased cycling, though overall fuel use was reduced. The analysis also indicated that the device was generally available to participate in HDPS control for greater than 90 per cent of the simulation time. The potential length of the participation time ranged from 1 to 800+min and depended upon the state of the μ-CHP system thermal buffer and prevailing heat loads. Probabilities for different participation times and modes were calculated.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.307
Threshold uncertainty score0.529

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.206
Teacher spread0.190 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of the Institution of Mechanical Engineers Part A Journal of Power and EnergySame topicThermodynamic and Exergetic Analyses of Power and Cooling SystemsFrench-language works237,207