MétaCan
Menu
Back to cohort
Record W2008362231 · doi:10.1016/s0886-3350(99)00335-1

AMO array multifocal lens versus monofocal correction in cataract surgery

2000· article· en· W2008362231 on OpenAlexaffabout
Kyle W. Brydon, Alexander C. Tokarewicz, Bruce D. Nichols

Bibliographic record

VenueJournal of Cataract & Refractive Surgery · 2000
Typearticle
Languageen
FieldMedicine
TopicOphthalmology and Visual Impairment Studies
Canadian institutionsLondon Health Sciences CentreWestern University
Fundersnot available
KeywordsMedicineOphthalmologyCataract surgeryLens (geology)PhacoemulsificationOptometryOpticsVisual acuityPhysics

Abstract

fetched live from OpenAlex

PURPOSE: To compare the functional capabilities of 15 patients (30 eyes) who had implantation of the Allergan Medical Optics (AMO) Array multifocal intraocular lens (IOL) with those of 13 patients (26 eyes) with an AMO monofocal IOL. SETTING: Department of Ophthalmology, The University of Western Ontario, Canada. METHODS: The objective capabilities of both groups were analyzed through visual acuity measurements for distance, near, and depth of focus. Subjective functionality was assessed through the use of a questionnaire that included the previously validated VF-14 index of visual function, a global measure of overall satisfaction with visual acuity, and questions related to the frequency of spectacle wear. RESULTS: Both groups had excellent corrected and uncorrected distance visual acuity postoperatively. The multifocal group had better acuity than the monofocal group at near with distance correction in place (70% versus 43% achieved J3 or better). The multifocal group also had significantly better depth of focus. Subjectively, both groups indicated high levels of satisfaction with visual function. However, the multifocal group indicated higher levels of satisfaction during the day, at night, and overall without spectacles. This result translated into less spectacle wear for both near and distance in the multifocal group. CONCLUSIONS: The results of this study indicate high patient satisfaction with the Array multifocal IOL and greater functional independence from spectacle wear, by objective and subjective patient measures, than with the monofocal IOL.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.115
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.058
GPT teacher head0.351
Teacher spread0.293 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations64
Published2000
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Cataract & Refractive SurgerySame topicOphthalmology and Visual Impairment StudiesFrench-language works237,207