MétaCan
Menu
Back to cohort
Record W2009757497 · doi:10.1118/1.2750966

Simplified skipped phase encoding and edge deghosting (SPEED) for imaging sparse objects with applications to MRA

2007· article· en· W2009757497 on OpenAlexaff
Zheng Chang, Qing‐San Xiang

Bibliographic record

VenueMedical Physics · 2007
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsUniversity of British Columbia
Fundersnot available
KeywordsAliasingComputer scienceEncoding (memory)Speedupk-spaceImaging phantomIterative reconstructionAlgorithmProjection (relational algebra)Image qualityFourier transformPhase (matter)SIGNAL (programming language)Compressed sensingComputer visionArtificial intelligenceMathematicsPhysicsOpticsImage (mathematics)Filter (signal processing)

Abstract

fetched live from OpenAlex

The fast imaging method named skipped phase encoding and edge deghosting (SPEED) has been demonstrated to reduce scan time considerably with typical magnetic resonance imaging data. In this work, SPEED is simplified with improved efficiency to accelerate the scan of sparse objects; we refer to this method as S-SPEED. S-SPEED partially samples k-space into two interleaved data sets, each with the same skip size of N but a different relative shift in phase encoding. The sampled data are then Fourier transformed into two ghosted images with N aliasing ghosts. Given the sparseness of signal distribution, the ghosted images are simply modeled with a single-layer structure, analogous to that used in maximum-intensity projection. With an algorithm based on a least-square-error solution, a deghosted image is solved, and a residual map is output for quality control. S-SPEED can be generalized to include more layers with additional acquisitions for refined results. Without differential filtering and full central k-space sampling, S-SPEED reduces scan time further and achieves more straightforward reconstruction, as compared with SPEED. In this work, S-SPEED is applied to accelerate magnetic resonance angiography (MRA) by taking advantage of the sparse nature of MRA data. With sparse phantom data and in vivo phase contrast MRA data, S-SPEED is demonstrated to achieve satisfactory results with an acceleration factor of 5.5 using a single coil.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.385
Teacher spread0.351 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207