MétaCan
Menu
← Back to cohort
Record W2010868710 · doi:10.1118/1.3469544

TH‐D‐BRB‐08: The Effect of Transverse Magnetic Fields on a Simulated In‐Line 6 MV Linac

2010· article· en· W2010868710 on OpenAlexaff
S Steciw, B. G. Fallone

Bibliographic record

VenueMedical Physics · 2010
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsLinear particle acceleratorTransverse planeMagnetic fieldLeakage (economics)Beam (structure)OpticsCathode rayMaterials scienceWaveguideElectronNuclear magnetic resonancePhysicsNuclear medicineNuclear physics

Abstract

fetched live from OpenAlex

Purpose: The linac waveguide is subjected to large magnetic fringe fields in a linac‐MR hybrid system. An investigation is performed to determine the effect of transverse magnetic fields on a simulated in‐line 6 MV medical linac. Method and Materials: The program PARMELA was used calculate the electron beam loss per cavity with the linac waveguide subjected to external transverse fields. BEAMnrc and DOSXYZnrc were used to calculate the effect on 40×40 and 20×20 cm2 field dose profiles and depth dose curves with the linac submersed in a transverse magnetic field. DOSRZnrc was used to determine the heating per cavity as a result of the beam loss and COMSOL was used to determine the resulting cavity resonant frequency changes due to cavity heating. Lastly a calculation of leakage radiation caused by the excessive beam loss was performed using BEAMnrc. Results: The beam loss was calculated to be 5±1 22±1 and 49±1% over nominal for 2 4 and 6 G magnetic fields respectively. The transverse magnetic fields caused a shifting of the electron spatial distribution at the target which resulted in a lateral shift of the dose profiles making 14.4% of all points fail a 1%/1mm acceptance criterion at a 6 G field. Through asymmetric jaw positions the lateral shift in the dose profiles was reduced such that only 0.5% of all points failed. The frequency of the accelerating mode changed by 0.03 Hz due to heating and a total leakage radiation of 0.007% of the radiation field was calculated. Conclusion: The 6 MV linac investigated showed sufficient tolerance to be used in transverse magnetic fields larger than earth's field. The shifts observed in the dose profiles were reduced through asymmetric jaw positions such that only 0.5 % of the points failed a 1 %/ 1 mm criterion at 6 G.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.273
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→