MétaCan
Menu
Back to cohort
Record W2012263043 · doi:10.2460/ajvr.70.3.334

Determination of cardiac output in anesthetized neonatal foals by use of two pulse wave analysis methods

2009· article· en· W2012263043 on OpenAlexaff
Andre Shih, Steeve Giguère, L. Chris Sanchez, Alexander Valverde, Hope Jankunas, Sheilah A. Robertson

Bibliographic record

VenueAmerican Journal of Veterinary Research · 2009
Typearticle
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsUniversity of Guelph
Fundersnot available
KeywordsCardiac outputMedicineAnesthesiaBlood pressurePopulationAnimal scienceHeart rateConcordance correlation coefficientPulse Wave AnalysisPulse wave velocityMathematicsHemodynamicsInternal medicineStatisticsBiology

Abstract

fetched live from OpenAlex

OBJECTIVE: To compare cardiac output (CO) measured by lithium arterial pressure waveform analysis (PULSECO) and CO measured by transpulmonary pulse contour analysis (PICCO) in anesthetized foals, with CO measured by use of lithium dilution (LIDCO) considered the criterion-referenced standard. SAMPLE POPULATION: 6 neonatal (1- to 4-day-old) foals that weighed 38 to 45 kg. Procedures-Foals were anesthetized and instrumented to measure direct blood pressure, heart rate, arterial blood gases, and CO. The CO was measured by use of PULSECO, PICCO, and LIDCO techniques. Measurements were converted to specific CO (sCO) values for statistical analysis. Measurements were obtained during low, intermediate, and high CO states. RESULTS: sCO ranged from 75.5 to 310 mL/kg/min. Mean +/- SD PICCO bias varied significantly among CO states and was -51.9 +/- 23.1 mL/kg/min, 20.0 +/- 19.5 mL/kg/min, and 87.2 +/- 19.5 mL/kg/min at low, intermediate, and high CO states, respectively. Mean PULSECO bias (11.0 +/- 37.5 mL/kg/min) was significantly lower than that of PICCO and did not vary among CO states. Concordance correlation coefficient between LIDCO and PULSECO was significantly greater than that between LIDCO and PICCO. The proportion of observations with a relative bias < +/- 30% was significantly lower with the PULSECO method than with the PICCO method. CONCLUSIONS AND CLINICAL RELEVANCE: Values for the PULSECO method were more reproducible and agreed better with values for the LIDCO method than did values for the PICCO method and were able to more accurately monitor changes in CO in anesthetized newborn foals.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.820
Threshold uncertainty score0.407

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0040.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.137
GPT teacher head0.490
Teacher spread0.353 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueAmerican Journal of Veterinary ResearchSame topicHemodynamic Monitoring and TherapyFrench-language works237,207