MétaCan
Menu
Back to cohort
Record W2012755837 · doi:10.1097/pcc.0b013e318220e7ea

Monitoring of standard hemodynamic parameters: Heart rate, systemic blood pressure, atrial pressure, pulse oximetry, and end-tidal CO2

2011· review· en· W2012755837 on OpenAlex
V. Ben Sivarajan, Desmond Bohn

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenuePediatric Critical Care Medicine · 2011
Typereview
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsSickKids Foundation
Fundersnot available
KeywordsMedicinePulse oximetryIntensive care medicineBlood pressureElectrocardiographyHeart rateRespiratory monitoringCardiologyInternal medicineAnesthesiaRespiratory system

Abstract

fetched live from OpenAlex

BACKGROUND: Continuous monitoring of various clinical parameters of hemodynamic and respiratory status in pediatric critical care medicine has become routine. The evidence supporting these practices is examined in this review. METHODOLOGY: A search of MEDLINE, EMBASE, PubMed, and the Cochrane Database was conducted to find controlled trials of heart rate, electrocardiography, noninvasive and invasive blood pressure, atrial pressure, end-tidal carbon dioxide, and pulse oximetry monitoring. Adult and pediatric data were considered. Guidelines published by the Society for Critical Care Medicine, the American Heart Association, the American Academy of Pediatrics, and the International Liaison Committee on Resuscitation were reviewed, including further review of references cited. RESULTS AND CONCLUSIONS: Use of heart rate, electrocardiography, noninvasive and arterial blood pressure, atrial pressure, pulse oximetry, and end-tidal carbon dioxide monitoring in the pediatric critical care unit is commonplace; this practice, however, is not supported by well-controlled clinical trials. Despite the majority of literature being case series, expert opinion would suggest that use of routine pulse oximetry and end-tidal carbon dioxide is the current standard of care. In addition, literature would suggest that invasive arterial monitoring is the current standard for monitoring in the setting of shock. The use of heart rate, electrocardiography. and atrial pressure monitoring is advantageous in specific clinical scenarios (postoperative cardiac surgery); however, the evidence for this is based on numerous case series only.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.500
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0060.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.042
GPT teacher head0.354
Teacher spread0.312 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it