MétaCan
Menu
Back to cohort
Record W2013151976 · doi:10.1118/1.4740206

Sci—Fri PM: Delivery — 11: Accuracy considerations in modern radiation oncology: An update

2012· article· en· W2013151976 on OpenAlexaff
Jacob Van Dyk, J Battista, GS Bauman

Bibliographic record

VenueMedical Physics · 2012
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsCancer Care OntarioWestern University
Fundersnot available
KeywordsRadiation oncologyMedical physicsRadiation treatment planningMedicineRadiation therapyImage-guided radiation therapyProcess (computing)Precision medicineComputer scienceRadiologyPathology

Abstract

fetched live from OpenAlex

The most recent reviews of accuracy requirements in radiation oncology were published in the 1990s, primarily in an era that was transitioning from 2-D to 3-D conformal radiation therapy (CRT). Since then, the technology associated with radiation oncology has changed dramatically. The combination of various forms of imaging for radiation therapy planning, treatment planning software, dose delivery technology including 4-D considerations as well as in-room daily image guidance has resulted in new perspectives on accuracy considerations. The underlying hypothesis for the use of these advanced technologies is that loco-regional control of cancer remains a significant barrier to cancer cure for many common cancers and that better dose distributions will translate into better outcomes. However, further clinical gain using these new technologies may be limited by single or compounded uncertainties associated with the entire treatment process. Thus, it is important to understand what factors should be considered in determining accuracy requirements as well as the realistic expectations of uncertainties that exist within the total treatment process. The need for accuracy is based on clinical requirements such as the steepness of dose-response curves, inherent heterogeneity in patient response to treatment, and the level of accuracy that is practically achievable. Statements on accuracy are dependent on the technology used and the reality of what is practically achievable and necessary. This review highlights some of the major differences between accuracy requirements as determined in the 2-D RT and 3-D CRT era versus the modern era of intensity modulated, image-guided, 4-D radiation therapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.011
Threshold uncertainty score0.036

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.005
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.003
Science and technology studies0.0000.001
Scholarly communication0.0020.003
Open science0.0010.001
Research integrity0.0020.003
Insufficient payload (model declined to judge)0.0110.007

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.341
Teacher spread0.319 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207