MétaCan
Menu
Back to cohort
Record W2013631672 · doi:10.1111/nmo.12346

Parameters for quantifying bolus retention with high‐resolution impedance manometry

2014· article· en· W2013631672 on OpenAlexaff
Zhiyue Lin, Frédéric Nicodème, Chu Yang Lin, B. Mogni, L. Friesen, Peter J. Kahrilas, John E. Pandolfino

Bibliographic record

VenueNeurogastroenterology & Motility · 2014
Typearticle
Languageen
FieldMedicine
TopicGastroesophageal reflux and treatments
Canadian institutionsCentre Hospitalier de l’Université de Montréal
FundersNational Institute of Diabetes and Digestive and Kidney Diseases
KeywordsBolus (digestion)FluoroscopyMedicineSupine positionNuclear medicineEsophagusHigh resolution manometrySwallowingPeristalsisSalineRadiologyAchalasiaInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: This study aimed to develop a methodology for quantifying esophageal bolus retention using a high-resolution esophageal impedance topography (EIT) technique. METHODS: The ability of impedance to quantify bolus retention was validated by comparison with concurrent fluoroscopic imaging (barium bolus) in 10 healthy subjects. High-resolution impedance manometry (HRIM) studies without fluoroscopy were performed in another 15 healthy subjects to define normal values using saline. HRIM data from each subject were analyzed using a MATLAB program customized for calculating the esophageal impedance integral (EII) prior to the contraction wave front as EII1 and after the contraction as EII2, and presented as a ratio of EII2/EII1, which was compared to the percent of barium areas retained in the esophagus on fluoroscopy determined by a blinded reviewer. KEY RESULTS: In 93% (37/40) of barium swallows, the results from the EIT method were in agreement with fluoroscopy results with one of three patterns: (1) 25 normal bolus transit, (2) eight bolus stasis, and (3) four retrograde escape or reflux. Three swallows (8%) had slight retention identified by EIT, but no retention detected by fluoroscopy. The correlation between percent of bolus retained in the esophagus detected by fluoroscopy and percent of bolus retention (EII2/EII1) after swallows with EIT method was r = 0.96 (p < 0.001) in supine and r = 0.69 (p < 0.001) in upright position. CONCLUSIONS & INFERENCES: The EII ratio (EII2/EII1) is a surrogate for the fraction of retained bolus after a swallow and this metric may be useful in better defining esophageal function.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.006
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.281
Teacher spread0.247 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations48
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueNeurogastroenterology & MotilitySame topicGastroesophageal reflux and treatmentsFrench-language works237,207