The Accuracy of the Use of Functional Hip Motions on Localization of the Center of the Hip

2012· article· en· W2014045248 on OpenAlexaff
Andrew Speirs, Daniel L. Benoit, Mélanie L. Beaulieu, Mario Lamontagne, Paul E. Beaulé

Bibliographic record

VenueHSS Journal® The Musculoskeletal Journal of Hospital for Special Surgery · 2012
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsOttawa HospitalUniversity of OttawaAgricultural Research Institute of Ontario
Fundersnot available
KeywordsPelvisFemurInstant centre of rotationAnatomyFunctional movementOrthodonticsMedicineRotation (mathematics)MathematicsGeometrySurgeryPhysical medicine and rehabilitation

Abstract

fetched live from OpenAlex

BACKGROUND: The hip joint is generally considered a ball-and-socket joint, the center of which is used as an anatomic landmark in functional analyses and by surgical navigation systems. The location of the hip center has been estimated using functional techniques using various limb motions. However, it is not clear which specific motions best predicted the functional center. PURPOSE: This study aims to compare the predicted functional center of the hip evaluated from multiplanar circumduction and star motions, and to compare this functional center with the geometric center. METHODS: Eight hips in four fresh-frozen cadavers were used and verified as morphologically normal in CT scans. Three-dimensional motion of each lower limb was recorded using arrays of reflective markers rigidly attached to the femur and pelvis. Each hip was manipulated to produce circumduction or star motion, i.e., abduction-adduction and flexion extension. The hip was then dissected and the bearing surface traced with a probe, from which a best-fit sphere was calculated. The functional center was calculated from the motion data and compared to the geometric technique. RESULTS: There was no difference between the functional hip center predicted by circumduction or star motions, although this was offset from the geometric hip center by up to 14 mm. For all except two hips, the functional center was less than 6 mm from the geometric hip in each anatomic direction. Test-retest differences were smaller for circumduction than for star motions. CONCLUSIONS: Estimation of the hip center based on motion of the femur relative to the pelvis could localize the geometric center of the joint within 14 mm and circumduction motions were more repeatable. CLINICAL RELEVANCE: Many surgical navigation systems make use of the functional hip center as a landmark for alignment or reconstruction. Errors associated with this would have a very minor influence in lower limb alignment, e.g., for knee reconstruction, but could affect proximal femoral geometry relevant to hip reconstruction.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.022
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.023

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.022
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.270
Teacher spread0.231 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2012
Admission routes1
Has abstractyes

Explore more