MétaCan
Menu
Back to cohort
Record W2014979579 · doi:10.1097/icl.0b013e3181812ba2

Uptake and Release of Ciprofloxacin-HCl From Conventional and Silicone Hydrogel Contact Lens Materials

2008· article· en· W2014979579 on OpenAlexaff
Alex Hui, Adrienne N. Boone, Lyndon Jones

Bibliographic record

VenueEye & Contact Lens Science & Clinical Practice · 2008
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsSilicone hydrogelContact lensLens (geology)Self-healing hydrogelsSiliconeDrugDrug deliveryCiprofloxacinBiomedical engineeringChromatographyChemistryMaterials sciencePharmacologyNanotechnologyAntibioticsMedicineOphthalmologyOpticsPolymer chemistryBiochemistryOrganic chemistry

Abstract

fetched live from OpenAlex

OBJECTIVES: To investigate the uptake and release characteristics of the antibiotic ciprofloxacin-HCl in conventional and silicone hydrogel lenses, and evaluate their potential as therapeutic drug delivery devices. METHODS: Nine differing soft contact lens materials were soaked in a 0.3% ciprofloxacin-HCl solution at 34 degrees C. The uptake of the drug into the lenses was measured by the change in concentration over 24 hours using fluorescence spectrophotometry. The lenses were then placed in a buffered saline solution, and the release of the drug from the lenses was also measured using spectrophotometry. RESULTS: The release of drug varied from 0.016 +/- 0.004 mg/lens for lotrafilcon A lenses to 0.42 +/- 0.03 mg/lens for etafilcon A lenses, with an average of 0.133 mg/lens. The 3 conventional lenses used in the study released a statistically significantly different amount of drug when compared with the silicone hydrogels. The release of drug was very rapid, with drug release reaching a plateau after no more than 10 minutes for the majority of the lenses. The majority of the lenses were able to release enough drug to achieve minimum inhibitory concentration 90 for most resistant ocular pathogens. Ciprofloxacin was found to heavily precipitate on the etafilcon A lenses during the release phase at physiologic pH. CONCLUSION: While balafilcon A released the most drug from the silicone hydrogel materials, all materials released the drug too quickly to be effective as drug delivery devices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.060
GPT teacher head0.365
Teacher spread0.305 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations83
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueEye & Contact Lens Science & Clinical PracticeSame topicOcular Surface and Contact LensFrench-language works237,207