MétaCan
Menu
Back to cohort
Record W2015194628 · doi:10.1039/b511882d

Microdialysis hollow fiber as a macromolecule trap for on-line coupling of solid phase microextraction and capillary electrophoresis

2006· article· en· W2015194628 on OpenAlexaff
Zhen Liu, Janusz Pawliszyn

Bibliographic record

VenueThe Analyst · 2006
Typearticle
Languageen
FieldEngineering
TopicMicrofluidic and Capillary Electrophoresis Applications
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsSolid-phase microextractionMicrodialysisAnalyteCapillary electrophoresisChromatographyChemistryAnalytical Chemistry (journal)Capillary electrochromatographyCapillary actionIsoelectric focusingMass spectrometryMaterials scienceGas chromatography–mass spectrometry

Abstract

fetched live from OpenAlex

On-line coupling of solid phase microextraction (SPME) and capillary electrophoresis (CE) is highly desirable due to the apparent advantages of the two techniques particularly in the context of microanalysis. However, the hyphenation is a significant challenge, because of band broadening and analyte carryover caused by the slow kinetics of analyte desorption in liquid phase. A novel strategy was presented in this study to overcome these problems. Analytes desorbed from an SPME fiber, which was held by an adapter, were first transferred by electrophoretic migration into a short piece of microdialysis hollow fiber, which was located at the inlet of a CE system. Analytes with molecular weights greater than the molecular weight cut-off of the microdialysis material were trapped in the microdialysis hollow fiber due to the dialysis effect. Then, under another electric field with different electrode polarity, the analytes trapped in the microdialysis hollow fiber migrated into the separation capillary and were separated. In the coupling approach, the microdialysis hollow fiber functioned as a macromolecule trap and a sample pre-concentrator as well. Band broadening was eliminated because the initial sample volume was very small (at nL level). Meanwhile, analyte carryover was eliminated because the desorption time could be as long as needed. Coupling of SPME with CE including two modes, capillary zone electrophoresis (CZE) and capillary isoelectric focusing (CIEF), was successfully demonstrated with proteins as test analytes. High efficiency and high resolution were obtained. The detection limits with UV absorbance whole-column imaging detection were 3.0 x 10(-7) and 3.0 x 10(-8) M (S/N = 3) for beta-lactoglobulin A and ovalbumin, respectively.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.015
Threshold uncertainty score0.602

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.262
Teacher spread0.253 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueThe AnalystSame topicMicrofluidic and Capillary Electrophoresis ApplicationsFrench-language works237,207