MétaCan
Menu
Back to cohort
Record W2016042230 · doi:10.1016/j.brachy.2012.03.002

A phantom study to assess accuracy of needle identification in real-time planning of ultrasound-guided high-dose-rate prostate implants

2012· article· en· W2016042230 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueBrachytherapy · 2012
Typearticle
Languageen
FieldMedicine
TopicProstate Cancer Diagnosis and Treatment
Canadian institutionsBC Cancer Agency
FundersBC Cancer AgencyVarian Medical Systems
KeywordsMedicineImaging phantomUltrasoundMedical physicsIdentification (biology)ProstateRadiologyNuclear medicineInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: High-dose-rate brachytherapy of the prostate is commonly performed using transrectal ultrasound (US) guidance, with CT imaging used for needle reconstruction and treatment planning. Transrectal ultrasound images can, however, be used for the entire process, allowing treatment without changes in the patient position. This study assesses needle reconstruction accuracy using US images. METHODS AND MATERIALS: Prostate phantoms were implanted with 10-18 needles. Three-dimensional US images were acquired, and needles were reconstructed using specialized software. A CT scan was also obtained. The image sets were registered and needle reconstruction errors were assessed. A dose plan was obtained using the US images and the dwell times were transferred to the CT reconstruction to obtain the true "delivered dose," which was evaluated using standard dosimetric parameters. RESULTS: Two sources of error were identified. First, reconstruction based on the bright echoes in the US images introduces a systematic error because these echoes correspond to the proximal wall of the needle, and not the center of the needle channel. If left uncorrected, this shift can lead to an underestimate of urethral doses. Second, incorrect needle tip identification can occur in the cranial-caudal direction. Errors up to 5.8mm were observed. A measurement of needle lengths protruding beyond the template can be used to compensate for this. CONCLUSIONS: Factors limiting the accuracy of US-based needle reconstruction have been identified. Once recognized, these errors can be corrected for, resulting in accurate implant geometry. This facilitates a treatment technique combining excellent anatomic definition, minimal prostate motion, and accurate dose planning and delivery.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.159
Threshold uncertainty score0.669

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.065
GPT teacher head0.381
Teacher spread0.316 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it