MétaCan
Menu
Back to cohort
Record W2019050226 · doi:10.1118/1.4814554

SU-E-T-119: Characteristics of TLD and PSLD Films for Photon and Electron Dose Measurements

2013· article· en· W2019050226 on OpenAlexaff
Chie Kurokawa, Akio Urushiyama, Tomoyuki Nishio, Seiichiro Sugimoto

Bibliographic record

VenueMedical Physics · 2013
Typearticle
Languageen
FieldMaterials Science
TopicLuminescence Properties of Advanced Materials
Canadian institutionsSaint Paul University
Fundersnot available
KeywordsThermoluminescent dosimeterIonization chamberIrradiationMaterials scienceElectronPhotonIonizationPhoton countingDosimetryOpticsRepeatabilityAtomic physicsPhysicsNuclear medicineChemistryRadiationIonNuclear physicsDosimeter

Abstract

fetched live from OpenAlex

Purpose: To evaluate the feature of our tissue-equivalent Thermoluminescense and Photoluminescense films for dose distribution measurements of photon and electron, and proton beams. Methods: Thermal and light fading, repeatability, and dose linearity (dose proportionality) were evaluated for our tissue-equivalent Thermoluminescense (TLD) and Photo-Stimulated luminescense (PSLD) films, which has 18 × 40 cm2 dimension and 0.09 mm thickness. These effects were examined at room temperature and under fluorescent light after irradiation by 6 MV photon. Three-dimensional dose distributions for photon, electron, and proton beams were also measured. Before the measurements of dose distributions, the irradiation was done to calibrate the response of each film. The readout was performed by 180 oC for TLD and blue LED lights for PSLD films, and generated light was detected with a CCD camera which has 1024 × 1024 pixels (FLIML 1001E-2, Finger Lakes Instrument). Results: After the irradiation, the fading of signals was 1–5% in one hour. It was observed that the variation for 10 sequent dose measurements at 200 cGy using 6 MV photons was less than 5%. Dose profiles for photon and electrons were obtained as smooth curve after the calibration. For photon measurements, PDDs with the TLD films well reproduced the results with ionization chamber, except for the surface region. The measured dose with TLD at surface is around 15%, which is lower more than 30% comparing to the dose with ionization chamber. Although obtained electron PDDs with TLD showed good agreement with that of ionization chamber, PDDs with PSLD showed slightly deviations from the chamber due to the contamination of high Z material. Conclusion: The characteristics of TLD and PSLD films were evaluated in order to make precise measurements. It is shown that they have the potential to measure the 3D dose distribution including low dose at surface. This work was supported by JSPS KAKENHI Grant Number 23791450.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.458

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.270
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicLuminescence Properties of Advanced MaterialsFrench-language works237,207