MétaCan
Menu
Back to cohort
Record W2019265265 · doi:10.1021/bm5003762

Chondroitin Sulfate Coatings Display Low Platelet but High Endothelial Cell Adhesive Properties Favorable for Vascular Implants

2014· article· en· W2019265265 on OpenAlex
P. Thalla, Hicham Fadlallah, Benoît Liberelle, Pauline Lequoy, Grégory De Crescenzo, Yahye Merhi, Sophie Lerouge

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueBiomacromolecules · 2014
Typearticle
Languageen
FieldMaterials Science
TopicElectrospun Nanofibers in Biomedical Applications
Canadian institutionsPolytechnique MontréalMontreal Heart InstituteÉcole de Technologie SupérieureCentre Hospitalier de l’Université de Montréal
FundersCanadian Institutes of Health ResearchNatural Sciences and Engineering Research Council of CanadaCanada Research Chairs
KeywordsPEG ratioChondroitin sulfateQuartz crystal microbalanceChemistryAdhesionBovine serum albuminProtein adsorptionCell adhesionPolyethylene glycolEthylene glycolFetal bovine serumBiophysicsAdsorptionMaterials scienceChromatographyBiochemistryGlycosaminoglycanCellOrganic chemistry

Abstract

fetched live from OpenAlex

This study highlights the advantages of chondroitin sulfate (CS) as a sublayer combining selective low-fouling properties, low-platelet adhesion and pro-adhesive properties on endothelial cells, making CS promising for vascular graft applications. These properties were evaluated by comparing CS with well-known low-fouling coatings such as poly(ethylene glycol) (PEG) and carboxymethylated dextran (CMD), which were covalently grafted on primary amine-rich plasma polymerized (LP) films. Protein adsorption studies by quartz crystal microbalance with dissipation monitoring (QCM-D) and fluorescence measurements showed that CS is as effective as PEG in reducing fibrinogen adsorption (~90% reduction). CS also largely reduced adsorption of bovine serum albumin (BSA) as well as fetal bovine serum (FBS) but to a lower extent than PEG and CMD surfaces (72% vs 85% for BSA and 66% vs 89% for FBS). Whole blood perfusion assays indicated that, while LP surfaces were highly reactive with platelets, PEG, CMD, and CS grafted surfaces drastically decreased platelet adhesion and activation to levels significantly lower than polyethylene terephthalate (PET) surfaces. Finally, while human umbilical vein endothelial cell (HUVEC) adhesion and growth were found to be very limited on PEG and CMD, they were significantly increased on CS compared to that on bare PET and reached similar values as those for tissue culture polystyrene positive controls. Interestingly, HUVEC retention during perfusion with blood was found to be excellent on CS but poor on PET. Overall, our results suggest that the CS surface has the advantage of promoting HUVEC growth and resistance to flow-induced shear stress while preventing fibrinogen and platelet attachment. Such a nonthrombogenic but endothelial-cell adhesive surface is thus promising to limit vascular graft occlusion.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.208
Teacher spread0.201 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it