MétaCan
Menu
Back to cohort

Right‐Side RF Ablation Using Remote Catheter Navigation: Experimental Results <i>In Vivo</i>

2011· article· en· W2019294979 on OpenAlexafffund
Yogesh Thakur, Douglas L. Jones, Allan C. Skanes, Raymond Yee, Maria Drangova

Bibliographic record

VenueJournal of Cardiovascular Electrophysiology · 2011
Typearticle
Languageen
FieldMedicine
TopicCardiac Arrhythmias and Treatments
Canadian institutionsWestern UniversityCanadian Institute for Advanced ResearchRobarts Clinical Trials
FundersCanadian Institutes of Health Research
KeywordsFluoroscopyMedicineCatheterAblationNavigation systemCatheter ablationCardiac AblationCardiac electrophysiologyRadiation exposureBiomedical engineeringComputer scienceReal-time computingSurgeryNuclear medicineCardiologyInternal medicineElectrophysiology

Abstract

fetched live from OpenAlex

INTRODUCTION: The close proximity between the interventionalist and patient during catheter-based interventions for cardiac arrhythmia exposes the interventionalist to harmful radiation. A prototype remote catheter navigation system (RCNS) has been developed to reduce occupational dose. The safety, feasibility of this RCNS and a comparison of remote and conventional navigation techniques is investigated in vivo. METHODS: Seven anatomical locations in the right side of the heart in porcine models were chosen as navigation targets. Using fluoroscopy and electrogram analysis, an experienced electrophysiology interventionalist manipulated a radiofrequency (RF) ablation catheter to each target using the RCNS and conventional navigation. Success rate, navigation time, exposure, exposure time and procedure time was recorded for all anatomical targets. Time to integrate the RCNS with the procedure suite was also measured. RESULTS: All targets were successfully reached with the RCNS and conventional navigation. No erratic catheter motion was observed with the RCNS whereas 1 operation failure occurred. The anatomical targets were found to have the largest effect on navigation time (P < 0.05), exposure (P < 0.05), and exposure time (P < 0.01), although the navigation method had little to no effect on the metrics. These results suggest that remote navigation procedures can be performed with navigation times comparable to conventional bedside navigation. CONCLUSION: Remote navigation with the RCNS may present a safe method of reducing occupational dose, while providing comparable navigation time with conventional bedside navigation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.262
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Cardiovascular ElectrophysiologySame topicCardiac Arrhythmias and TreatmentsFrench-language works237,207