MétaCan
Menu
Back to cohort
Record W2019608960 · doi:10.1016/j.carj.2009.02.035

Radiation Dose from Diagnostic Computed Tomography in Saskatchewan

2009· article· en· W2019608960 on OpenAlexafffundabout
David A. Leswick, Nida S. Syed, Chance S. Dumaine, Hyun J. Lim, D. Fladeland

Bibliographic record

VenueCanadian Association of Radiologists Journal · 2009
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsMcMaster UniversityUniversity of SaskatchewanRoyal University Hospital
FundersMinistry of Advanced EducationUniversity of Saskatchewan
KeywordsMedicineNuclear medicinePelvisComputed tomographyAbdomenEffective dose (radiation)Radiation doseRadiologyTomography

Abstract

fetched live from OpenAlex

OBJECTIVE: To calculate the effective dose from diagnostic computed tomography (CT) scans in Saskatchewan, Canada, and compare with other reported dose levels. METHODS: Data from CT scans were collected from 12 scanners in 7 cities across Saskatchewan. The patient age, scan type, and selected technique parameters including the dose length product and the volume computed tomography dose index were collected for a 2-week period. This information then was used to calculate effective doses patients are exposed to during CT examinations. Data from 2,061 clinically indicated CT examinations were collected, and of them 1,690 were eligible for analysis. Every examination during a 2-week period was recorded without selection. RESULTS: The average provincial estimated patient dose was as follows: head, 2.7 mSv (638 scans; standard deviation [SD], +/-1.6); chest, 11.3 mSv (376 scans; SD, +/-8.9); abdomen-pelvis, 15.5 mSv (578 scans; SD, +/-10.0); abdomen, 11.7 mSv (80 scans; SD, +/-11.48), and pelvis, 8.6 mSv (18 scans; SD, +/-6.04). Significant variation in dose between the CT scanners was observed (P = .049 for head, P = .001 for chest, and P = .034 for abdomen-pelvis). CONCLUSIONS: Overall, the estimated dose from diagnostic CT examinations was similar to other previously published Canadian data from British Columbia. This dose varied slightly from some other published standards, including being higher than those found in a review conducted in the United Kingdom in 2003.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.079
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.242
Teacher spread0.234 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2009
Admission routes3
Has abstractyes

Explore more

Same venueCanadian Association of Radiologists JournalSame topicRadiation Dose and ImagingFrench-language works237,207