A Case Study of the Climate Factor on Thermal Comfort for Hostel Occupants in Universiti Sains Malaysia (USM), Penang, Malaysia

2011· article· en· W2022458834 on OpenAlexvenueno aff
Sulaiman Ramdan Wafi, Mohd Rodzi Ismail, Egbal Mohammed Ahmed

Bibliographic record

VenueJournal of Sustainable Development · 2011
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsnot available
Fundersnot available
KeywordsThermal comfortWet-bulb globe temperatureAir temperatureAir velocityEnvironmental scienceOperative temperatureMean radiant temperatureRelative humidityGeographyThermal sensationLogistic regressionMeteorologyArchitectural engineeringClimate changeEngineeringMathematicsStatisticsEcology

Abstract

fetched live from OpenAlex

This paper investigates the environmental thermal comfort in hostel accommodations in USM Penang, Malaysia. Hostel occupants’ physical and psychological wellbeing depend very much on the thermal comfort performance of their environment. Thermal comfort is very much affected by climate factors such as air temperature, globe temperature, radiant temperature and air velocity. Nine hostels in USM Penang, Malaysia were selected for a field study to predict the thermal comfort level of the student occupants. Altogether a total of nine hundred and twenty-four respondents from the sample hostels participated in a questionnaire survey on their thermal environment perception and level of indoor comfort. Air temperature, air velocity, relative humidity and radiant temperature were monitored, observed and measured daily for a week from 8am to 12 midnight. ISO software (comfort calculator ISO 7730) was used to calculate climatic data, clothing, activities of respondents and the value of the PMV and PPD in order to obtain the vote for the quality of thermal comfort in the hostel room. The aim of this research was to investigate the thermal comfort level of the hostel occupant from the analysis of logistic regression and regression line. The results showed that there were significant differences (P < 0.05) between all parameters inside and outside the hostels in addition to the thermal comfort level for male and female occupants. This study predicted that climate affects thermal comfort in hostels located in a warm humid climate zone and also determined the actual thermal comfort in the hostel rooms. This study should be useful for optimizing the thermal comfort level in Malaysia.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.810
Threshold uncertainty score0.418

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.214
Teacher spread0.192 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Sustainable DevelopmentSame topicBuilding Energy and Comfort OptimizationFrench-language works237,207