MétaCan
Menu
← Back to cohort
Record W2023076045 · doi:10.1118/1.4740091

Sci-Thur AM: Planning - 06: Planning target volume margin suitability in lung stereotactic body radiation therapy: A preliminary evaluation using cone-beam computed tomography

2012· article· en· W2023076045 on OpenAlexaff
Lindsay Mathew, Anand Swaminath, J Szabo, Marcin Wierzbicki

Bibliographic record

VenueMedical Physics · 2012
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsMcMaster UniversityJuravinski Cancer Centre
Fundersnot available
KeywordsMargin (machine learning)Radiation treatment planningCone beam computed tomographyNuclear medicineVoxelMedicineRadiation therapyImage registrationCone beam ctPinnacleDosimetryComputed tomographyRadiologyComputer scienceComputer visionImage (mathematics)

Abstract

fetched live from OpenAlex

Stereotactic body radiation therapy (SBRT) requires precise delivery of radiation to the target; intra- and inter-fraction lung tumour motion may adversely impact local tumour control. The purpose of this study was to retrospectively evaluate the impact of planning target volume (PTV) margin size on the coverage of the internal target volume (ITV) as localized in pre- and post-treatment cone-beam computed tomography (CBCT) images. Data from two patients undergoing SBRT were evaluated. For planning, free-breathing and 4DCT scans were performed, and used to contour the ITV. A 5mm margin was added to create the PTV. During treatment, 14 CBCTs were collected pre- and post-beam delivery. A data set comprising the average 4DCT intensities where available and treatment planning CT intensities for voxels that were beyond the field of view of the 4DCT was constructed. Registration of the combined planning image to each CBCT was performed using a deformable image registration algorithm. The transformations aligning the combined planning image with the CBCTs were applied to the planning ITV to obtain the treatment ITVs. For each CBCT, the fraction of treatment ITV within the PTV was determined using Boolean logic. This was repeated for various PTV margins ranging from 0 to 10 mm at 1mm intervals. The 3 and 5 mm PTV margins covered 95.1 ± 5.9% and 99.0 ± 2.0% of the ITV, respectively. Analysis of additional patients will be performed to confirm these preliminary results, which reinforce the use of a 5mm PTV margin for lung SBRT.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.331
Teacher spread0.305 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→