Efficacy and Safety of Celivarone, With Amiodarone as Calibrator, in Patients With an Implantable Cardioverter-Defibrillator for Prevention of Implantable Cardioverter-Defibrillator Interventions or Death
Bibliographic record
Abstract
BACKGROUND: Celivarone is a new antiarrhythmic agent developed for the treatment of ventricular arrhythmias. This study investigated the efficacy and safety of celivarone in preventing implantable cardioverter-defibrillator (ICD) interventions or death. METHODS AND RESULTS: Celivarone (50, 100, or 300 mg/d) was assessed compared with placebo in this randomized, double-blind, placebo-controlled, parallel-group study. Amiodarone (200 mg/d after loading dose of 600 mg/d for 10 days) was used as a calibrator. A total of 486 patients with a left ventricular ejection fraction ≤40% and at least 1 ICD intervention for ventricular tachycardia or ventricular fibrillation in the previous month or ICD implantation in the previous month for documented ventricular tachycardia/ventricular fibrillation were randomized. Median treatment duration was 9 months. The primary efficacy end point was occurrence of ventricular tachycardia/ventricular fibrillation-triggered ICD interventions (shocks or antitachycardia pacing) or sudden death. The proportion of patients experiencing an appropriate ICD intervention or sudden death was 61.5% in the placebo group; 67.0%, 58.8%, and 54.9% in the celivarone 50-, 100-, and 300-mg groups, respectively; and 45.3% in the amiodarone group. Hazard ratios versus placebo for the primary end point ranged from 0.860 for celivarone 300 mg to 1.199 for celivarone 50 mg. None of the comparisons versus placebo were statistically significant. Celivarone had an acceptable safety profile. CONCLUSIONS: Celivarone was not effective for the prevention of ICD interventions or sudden death. CLINICAL TRIAL REGISTRATION: http://www.clinicaltrials.gov. Unique identifier: NCT00993382.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".