MétaCan
Menu
Back to cohort
Record W2024630611 · doi:10.1118/1.3429131

Enhancements to commissioning techniques and quality assurance of brachytherapy treatment planning systems that use model‐based dose calculation algorithmsa)

2010· article· en· W2024630611 on OpenAlexafffund
Mark J. Rivard, Luc Beaulieu, Firas Mourtada

Bibliographic record

VenueMedical Physics · 2010
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversité LavalCentre hospitalier universitaire de Québec
FundersNational Cancer InstituteU.S. Food and Drug AdministrationCentre Hospitalier Universitaire de Québec
KeywordsQuality assuranceBrachytherapyRadiation treatment planningMedical physicsDosimetryProject commissioningMedicineRadiation therapySystems engineeringComputer scienceNuclear medicineRadiologyEngineering

Abstract

fetched live from OpenAlex

The current standard for brachytherapy dose calculations is based on the AAPM TG-43 formalism. Simplifications used in the TG-43 formalism have been challenged by many publications over the past decade. With the continuous increase in computing power, approaches based on fundamental physics processes or physics models such as the linear-Boltzmann transport equation are now applicable in a clinical setting. Thus, model-based dose calculation algorithms (MBDCAs) have been introduced to address TG-43 limitations for brachytherapy. The MBDCA approach results in a paradigm shift, which will require a concerted effort to integrate them properly into the radiation therapy community. MBDCA will improve treatment planning relative to the implementation of the traditional TG-43 formalism by accounting for individualized, patient-specific radiation scatter conditions, and the radiological effect of material heterogeneities differing from water. A snapshot of the current status of MBDCA and AAPM Task Group reports related to the subject of QA recommendations for brachytherapy treatment planning is presented. Some simplified Monte Carlo simulation results are also presented to delineate the effects MBDCA are called to account for and facilitate the discussion on suggestions for (i) new QA standards to augment current societal recommendations, (ii) consideration of dose specification such as dose to medium in medium, collisional kerma to medium in medium, or collisional kerma to water in medium, and (iii) infrastructure needed to uniformly introduce these new algorithms. Suggestions in this Vision 20/20 article may serve as a basis for developing future standards to be recommended by professional societies such as the AAPM, ESTRO, and ABS toward providing consistent clinical implementation throughout the brachytherapy community and rigorous quality management of MBDCA-based treatment planning systems.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.720
Threshold uncertainty score0.659

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.047
GPT teacher head0.372
Teacher spread0.325 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations59
Published2010
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207