MétaCan
Menu
← Back to cohort
Record W2024994735 · doi:10.1118/1.2760751

SU‐FF‐T‐97: Characterization of Amorphous Silicon Flat Panel Imager for Dose Measurements

2007· article· en· W2024994735 on OpenAlexaff
J Szabo, Rao Khan, Orest Ostapiak

Bibliographic record

VenueMedical Physics · 2007
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsHamilton Regional Laboratory Medicine ProgramJuravinski Cancer Centre
Fundersnot available
KeywordsIonization chamberImaging phantomLinear particle acceleratorNuclear medicineImage-guided radiation therapyMaterials scienceReproducibilityDose profileOpticsPercentage depth dose curveDosimetryPixelMedical imagingBeam (structure)Biomedical engineeringPhysicsIonizationMedicineMathematicsRadiology

Abstract

fetched live from OpenAlex

Purpose: The major objective of the work was to categorize the dosimetric response of a Varian aS500 type Electronic Portal Imaging Device (EPID) for dose measurements. Method and Materials: For a 6MV beam from a Varian 21EX linear accelerator, reproducibility of EPID pixel response, dose rate effect, and cumulative dose linearity were studied. In addition, scatter characteristics and depth doses were also determined using the EPID. A Capintec ion chamber in a polystyrene miniphantom and a Wellhöfer water phantom were used for comparative measurements. Results: The EPID response was found to be independent of dose rates from 100 MU/min to 600 MU/min at larger source to detector distances. However, pixel saturation was observed for dose rates beyond 300 MU/min with the EPID placed at the isocentre. Raw pixel response was reproducible to within 2 % when measured over a period of 6 weeks. Changes in scatter conditions with field size were also measured for the EPID. The EPID scatter was found to be in between 5 to 10 cm of a full water phantom. The gray scale response is linear with the dose to the portal imager. The validity of inverse square relationship was also tested to be within 0.5%, for the EPID at various distances from the source. Conclusions: The depth dose data measured with EPID showed good correspondence with that measured with a thimble type ionization chamber in a water phantom. Compared to ionization chamber data, open beam profiles measured with EPID show flat response in high dose region, rapid fall‐off in high dose gradients (> 30%/cm), and higher penumbra tail. The agreement with the ion chamber measurements could be improved if the flood field correction is performed to restore off‐axis variation of beam profile. In general the EPID qualifies as a useful tool for planar dose measurements.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.301
Teacher spread0.267 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→