MétaCan
Menu
Back to cohort
Record W2026799534 · doi:10.1002/ccd.25823

Multicenter evaluation of transcatheter aortic valve replacement using either <scp>SAPIEN XT</scp> or <scp>C</scp>ore<scp>V</scp>alve: Degree of device oversizing by computed‐tomography and clinical outcomes

2015· article· en· W2026799534 on OpenAlexaff
Danny Dvir, John G. Webb, Nicolò Piazza, Philipp Blanke, Marco Barbanti, Sabine Bleiziffer, David Wood, Darren Mylotte, Alex Wilson, Dion Stub, Corrado Tamburino, Rüdiger Lange, Jonathon Leipsic

Bibliographic record

VenueCatheterization and Cardiovascular Interventions · 2015
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsMcGill University Health CentreSt. Paul's Hospital
Fundersnot available
KeywordsMedicinePerimeterValve replacementCardiac skeletonCardiologyInternal medicineAortic valveStroke (engine)Computed tomographyNuclear medicineSurgeryAortic valve replacementStenosisMathematicsGeometry

Abstract

fetched live from OpenAlex

OBJECTIVE: To analyze the association between computed-tomography-derived degrees of device oversizing and clinical outcomes during transcatheter aortic valve replacement (TAVR). BACKGROUND: Previous reports suggest that different devices reach optimal results with different degrees of device oversizing. Therefore, similar sized devices of different types (SAPIEN XT and CoreValve) may be favored in different annular ranges and a case considered borderline between two sizes of a specific device might be within a favorable range of another. METHODS AND RESULTS: A multicenter registry of 615 consecutive transfemoral TAVR procedures using either SAPIEN XT or CoreValve was analyzed. A first group of 190 patients had annular sizes for which only moderate oversizing degree was feasible (5-20% by area or 2.5-9.5% by perimeter). A second group included 178 patients that had annulus size for which only large oversizing degree was feasible (20.1-35% by area or 9.6-16.2% by perimeter). In the "only large oversizing feasible group" there were more annular rupture events in patients treated by SAPIEN XT valve as compared to those treated by CoreValve (3.4% vs. 0%, P = 0.04). In the "only moderate oversizing feasible group", those treated by CoreValve had more post balloon dilatation and 30-day major stroke in comparison with those treated by SAPIEN XT (16.1% vs. 7.7%, P = 0.04 and 8% vs. 1.3%, P = 0.02, respectively). CONCLUSIONS: Optimal clinical performance of CoreValve and SAPIEN XT appears to be reached with different degrees of oversizing. Certain annular sizes that allow for only moderate or large oversizing, but not both, appear to benefit from a device specific approach.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.028
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.007
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.107
GPT teacher head0.392
Teacher spread0.285 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations68
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueCatheterization and Cardiovascular InterventionsSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207