MétaCan
Menu
Back to cohort
Record W2026867235 · doi:10.1089/lrb.2012.0020

Determining the Precision of Dual Energy X-Ray Absorptiometry and Bioelectric Impedance Spectroscopy in the Assessment of Breast Cancer-Related Lymphedema

2013· article· en· W2026867235 on OpenAlexafffund
Anne Newman, Léonard Rosenthall, Anna Towers, Pamela Hodgson, Carol A Shay, Dorit Tidhar, Antonio Viganò, Robert D. Kilgour

Bibliographic record

VenueLymphatic Research and Biology · 2013
Typearticle
Languageen
FieldMedicine
TopicLymphatic System and Diseases
Canadian institutionsConcordia UniversityMcGill University Health Centre
FundersMcGill University
KeywordsLymphedemaMedicineNuclear medicineBreast cancerDual-energy X-ray absorptiometryBioelectrical impedance analysisExtracellular fluidIn vivo magnetic resonance spectroscopyRadiologyBone mineralBody mass indexMagnetic resonance imagingCancerOsteoporosisInternal medicineChemistryExtracellular

Abstract

fetched live from OpenAlex

BACKGROUND: The composition of breast cancer-related lymphedema (BCRL) has been shown to evolve from the initial accumulation of fluid to the development of fibrotic lesions and abnormal fat deposition. Therefore, precise and reliable assessments of BCRL are required to develop accurate staging and management. Although dual energy x-ray absorptiometry (DXA) and bioelectric impedance spectroscopy (BIS) have been used to assess BCRL, no study has evaluated the precision of these two modalities in the same cohort. METHODS AND RESULTS: We determined the precision of DXA and BIS in lymphedematous (LE) and nonaffected (NA) arms of 24 women with Stage II unilateral BCRL. Precision was calculated from the results of paired bilateral arm measurements obtained from DXA scans measuring fat, lean, and bone mineral masses, BIS measuring extracellular fluid (ECF) and total fluid volume, and circumferential tape measurements (CM) of the arms to calculate the anatomic volume. Precision error was expressed as the root mean square (RMS) of the coefficients of variation (%CV) and standard deviations (SD). RESULTS: The precisions of DXA and BIS varied from 1.16% (DXA measurements of LE arm total volume) to 1.86% (BIS LE arm total fluid volume) and from 0.95% (DXA lean mass of NA arm) to 1.72% (DXA BMC of NA arm). Precision of CM measures of arm volume were 1.71% CV for LE arm and 2.51% CV for NA arm. The fat and lean masses of the LE arm exceeded the NA arm by about 15% (p<0.0001). ECF and total fluid volume of LE arm was 22.6% and 19% greater than the NA arm (p<0.0001), respectively. CONCLUSION: For BCRL, these findings suggest that DXA and BIS are two measurement instruments that provide acceptable levels of precision for the measurement of arm lean mass, fat mass and ECF volume, respectively.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.012
metaresearch head score (Gemma)0.030
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.012
Threshold uncertainty score0.061

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0120.030
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.048
GPT teacher head0.401
Teacher spread0.353 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations47
Published2013
Admission routes2
Has abstractyes

Explore more

Same venueLymphatic Research and BiologySame topicLymphatic System and DiseasesFrench-language works237,207