MétaCan
Menu
Back to cohort
Record W2026885452 · doi:10.1152/ajpheart.00228.2013

Side-specific mechanical properties of valve endothelial cells

2014· article· en· W2026885452 on OpenAlexfundno aff
Michele Miragoli, Magdi H. Yacoub, Ismaı̈l El-Hamamsy, Jose L. Sanchez‐Alonso, Alexey Moshkov, Napachanok Mongkoldhumrongkul, Muralidhar Padala, Saravanan Paramagurunathan, Padmini Sarathchandra, Yuri E. Korchev, Julia Gorelik, Adrian H. Chester

Bibliographic record

VenueAmerican Journal of Physiology-Heart and Circulatory Physiology · 2014
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicCellular Mechanics and Interactions
Canadian institutionsnot available
FundersBiotechnology and Biological Sciences Research CouncilEngineering and Physical Sciences Research CouncilCanadian Institutes of Health Research
KeywordsCell biologyChemistryMaterials scienceBiomedical engineeringMedicineBiology

Abstract

fetched live from OpenAlex

Aortic valve endothelial cells (ECs) function in vastly different levels of shear stress. The biomechanical characteristics of cells on each side of valve have not been investigated. We assessed the morphology and mechanical properties of cultured or native valve ECs on intact porcine aortic valve cusps using a scanning ion conductance microscope (SICM). The autocrine influence of several endothelial-derived mediators on cell compliance and the expression of actin were also examined. Cells on the aortic side of the valve are characterized by a more elongated shape and were aligned along a single axis. Measurement of EC membrane compliance using the SICM showed that the cells on the aortic side of intact valves were significantly softer than those on the ventricular side. A similar pattern was seen in cultured cells. Addition of 10(-6) M of the nitric oxide donor sodium nitroprusside caused a significant reduction in the compliance of ventricular ECs but had no effect on cells on the aortic side of the valve. Conversely, endothelin-1 (10(-10)-10(-8) M) caused an increase in the compliance of aortic cells but had no effect on cells on the ventricular side of the valve. Aortic side EC compliance was also increased by 10(-4) M of the nitric oxide synthase inhibitor NG-nitro-L-arginine methyl ester. Immunofluorescent staining of actin filaments revealed a great density of staining in ECs on the ventricular surface. The expression of actin and the relative membrane compliance of ECs on both side of the valve were not affected by ventricular and aortic patterns of flow. This study has shown side-specific differences in the biomechanics of aortic valve ECs. These differences can have important implications for valve function.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.046
Threshold uncertainty score0.654

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.219
Teacher spread0.208 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueAmerican Journal of Physiology-Heart and Circulatory PhysiologySame topicCellular Mechanics and InteractionsFrench-language works237,207