MétaCan
Menu
Back to cohort
Record W2027093767 · doi:10.1080/146288401753514489

A single center experience with the newly designed R Stent in small coronary vessels

2001· article· en· W2027093767 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

aboutThe title or abstract carries a Canadian signal from the geographic lexicon.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueInternational Journal of Cardiovascular Interventions · 2001
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineCoronary arteriesStentCardiologyRight coronary arteryArteryCircumflexAngioplastyInternal medicineStenosisCoronary stentUnstable anginaAnginaBalloonRadiologySurgeryRestenosisMyocardial infarctionCoronary angiography

Abstract

fetched live from OpenAlex

BACKGROUND: Over the past 10 years stents have been used more frequently for the treatment of de novo coronary artery stenosis. Initally these devices were used primarily in coronary arteries with diameters ranging from 3.0 to 4.0 mm. Traditionally, coronary arteries less than 3.0 mm in diameter were treated with only balloon angioplasty, due to the unavailablity of flexible, low profile, small diameter stents. In the past three years, many stents have been designed to be implanted in small coronary arteries. OBJECTIVE: The objective of this study was to evaluate the safety and feasiblity of the R Stent in patients with coronary lesions located in coronary arteries with a reference diameter 2.5-3.0 mm. METHODS AND RESULTS: Between November 1998 and September 1999, 32 patients with stable (37%) and unstable (63%) angina treated with the R Stent were included in this study. The treated lesions were in the right coronary artery (RCA) (n = 13), left cirumflex coronary artery (LCX) (n = 10), and left anterior descending coronary artery (LAD) (n = 9). Of these lesions thirteen were anatomically complex. Stent deployment was successful in 97% with one crossing failure in a patient with a vessel tortuosity of greater than 75 degrees of the circumflex artery. No post-procedual major adverse cardiac and cerebrovascular event (MACCE) occurred within 30 days of stent implantation. After the procedure, patients were scheduled for a two-week telephone follow-up and a one-month clinical evaluation. At 30 days, only one patient (3%) experienced the recurrence of angina Canadian cardiovascular society classification ((CCS) Class 2). All other patients were event and angina free. CONCLUSION: This first clinical experience in patients with small vessel disease shows that the use of the R stent is safe and feasible with low rates of acute stent thrombosis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.391
Threshold uncertainty score0.442

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.002
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.048
GPT teacher head0.300
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it