MétaCan
Menu
Back to cohort
Record W2027093767 · doi:10.1080/146288401753514489

A single center experience with the newly designed R Stent in small coronary vessels

2001· article· en· W2027093767 on OpenAlexaboutno aff
Erdoğan İlkay, Ilgın Karaca, Arif Karadaban, Ali Erhan Kılıçoğlu, Mehmet Yalnız, Yılmaz Özbay, Ahmet Karakurt, Mehmet Akbulut, Nadi Arslan

Bibliographic record

VenueInternational Journal of Cardiovascular Interventions · 2001
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineCoronary arteriesStentCardiologyRight coronary arteryArteryCircumflexAngioplastyInternal medicineStenosisCoronary stentUnstable anginaAnginaBalloonRadiologySurgeryRestenosisMyocardial infarctionCoronary angiography

Abstract

fetched live from OpenAlex

BACKGROUND: Over the past 10 years stents have been used more frequently for the treatment of de novo coronary artery stenosis. Initally these devices were used primarily in coronary arteries with diameters ranging from 3.0 to 4.0 mm. Traditionally, coronary arteries less than 3.0 mm in diameter were treated with only balloon angioplasty, due to the unavailablity of flexible, low profile, small diameter stents. In the past three years, many stents have been designed to be implanted in small coronary arteries. OBJECTIVE: The objective of this study was to evaluate the safety and feasiblity of the R Stent in patients with coronary lesions located in coronary arteries with a reference diameter 2.5-3.0 mm. METHODS AND RESULTS: Between November 1998 and September 1999, 32 patients with stable (37%) and unstable (63%) angina treated with the R Stent were included in this study. The treated lesions were in the right coronary artery (RCA) (n = 13), left cirumflex coronary artery (LCX) (n = 10), and left anterior descending coronary artery (LAD) (n = 9). Of these lesions thirteen were anatomically complex. Stent deployment was successful in 97% with one crossing failure in a patient with a vessel tortuosity of greater than 75 degrees of the circumflex artery. No post-procedual major adverse cardiac and cerebrovascular event (MACCE) occurred within 30 days of stent implantation. After the procedure, patients were scheduled for a two-week telephone follow-up and a one-month clinical evaluation. At 30 days, only one patient (3%) experienced the recurrence of angina Canadian cardiovascular society classification ((CCS) Class 2). All other patients were event and angina free. CONCLUSION: This first clinical experience in patients with small vessel disease shows that the use of the R stent is safe and feasible with low rates of acute stent thrombosis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.048
GPT teacher head0.300
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2001
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of Cardiovascular InterventionsSame topicCoronary Interventions and DiagnosticsFrench-language works237,207