MétaCan
Menu
Back to cohort
Record W2027772280 · doi:10.3109/0284186x.2013.822552

Clinical impact of using the deterministic patient dose calculation algorithm Acuros XB for lung stereotactic body radiation therapy

2013· article· en· W2027772280 on OpenAlexaff
Hongwei Liu, Zoann Nugent, R Clayton, Peter Dunscombe, Harold Lau, Rao Khan

Bibliographic record

VenueActa Oncologica · 2013
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsCancerCare ManitobaAlberta Cancer FoundationUniversity of Calgary
Fundersnot available
KeywordsMedicineNuclear medicineLung cancerRadiation therapyLogistic regressionAlgorithmRadiologyMathematicsInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: To evaluate the clinical impact of using the deterministic dose calculation algorithm, Acuros XB, for early stage lung cancer patients undergoing stereotactic body radiotherapy (SBRT). MATERIAL AND METHODS: Seventy-seven stage I non-small cell lung cancer patients who underwent lung SBRT from 2008 to 2012 at our center were included in this study. All treatment plans originally calculated by the anisotropic analytical algorithm (AAA) were recalculated using the AAA and Acuros XB algorithms with identical monitor units and beam arrangements. The dose, dose distribution, conformality number (CN) and heterogeneity index (HI) of the target were determined for each plan. A paired matched t-test was used to evaluate the difference between the mean dose, the dose distribution, and the CN and HI for the target. The importance of tumor (volume, location), patient (pulmonary functional, body mass index) and treatment (number of SBRT beams) on the dose distributions obtained from the two algorithms was statistically determined using linear regression analyses. RESULTS: The mean target dose was same for both algorithms. Compared to AAA, a small and significant difference in dose distribution in the target was found for the Acuros XB algorithm, resulting in lower conformity (-2.1%, p < 0.0001) and higher heterogeneity (p < 0.0001) of dose. Single logistic regression identified pulmonary function, number of beams and target location as being correlated with the difference of CN between the two calculations. Multivariate analysis indicated that the patient's pulmonary function (p = 0.0296) was the only predictor for the difference in conformality between the two dose calculation algorithms. CONCLUSIONS: In lung SBRT, the patient's pulmonary function is responsible for the difference in target dose distribution between the Acuros XB and AAA algorithms. The Acuros XB algorithm could be used to advantage in patients with compromised pulmonary function based on its accurate modeling of lung tissue in comparison to AAA.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.012
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.012
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.403
Teacher spread0.367 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations45
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueActa OncologicaSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207